Доступ предоставлен для: Guest
Journal of Long-Term Effects of Medical Implants
Главный редактор: Subrata Saha (open in a new tab)

Выходит 4 номеров в год

ISSN Печать: 1050-6934

ISSN Онлайн: 1940-4379

SJR: 0.184 SNIP: 0.485 CiteScore™:: 1.1 H-Index: 39

Indexed in

A Biomechanical Study of Unilateral Posterior Atlantoaxial Transarticular Screw Fixation

Том 15, Выпуск 1, 2005, pp. 33-38
DOI: 10.1615/JLongTermEffMedImplants.v15.i1.40
Get accessGet access

Краткое описание

The purpose of this study was to investigate the fixation of C1−C2 instability with the use of a unilateral screw. Transarticular screw placement across C1−C2 may be contra-indicated in up to 20% of specimens on at least one side because of anatomic variations or other pathological processes. Hence the current study looks into unilateral screw fixation of C1−C2 instability. Eight cervical spine specimens, C1 through C5, were harvested from fresh human cadavers (4 male and 4 female) of average age 67 years (54−80). C1 and C2−C5 vertebrae were potted to allow motion only at the C1−C2 articulation. Cutting the transverse ligament on both sides of the odontoid and the tectorial membrane destabilized the specimens. Transarticular screw fixation of C1−C2 was performed in a manner similar to the technique described by Magerl. The stability was tested after fixation with one transarticular screw together with a posterior graft and wire. Placement of the screw was randomized, resulting in half the specimens receiving screws on the right side and the remaining half on the left side. The stiffness of the C1−C2 articulation was tested in rotation, lateral bending, flexion, and anterior translation in random order. The rotational stiffness was 1.44 ± 0.44 N-m/deg, while lateral bending stiffness values were 2.33 ± 1.14 N-m/mm (right bending) and 2.81 ± 1.36 N-m/mm (left bending). The stiffness value in flexion was 0.813 ± 0.189 N-m/mm and in translation 67.1 ± 25.1 N/m. It was found that stability after unilateral transarticular screw fixation was less than that previously reported after bilateral transarticular screw fixation, but similar to that found with modified Brooks posterior wiring, which has been shown to provide better stability than other posterior wiring methods, and fusion rates of 96% have been reported.
We concluded that C1−C2 unilateral posterior transarticular screw fixation with supplemental posterior graft and wiring would confer adequate stability in cases where bilateral screw placement is contraindicated.

ЦИТИРОВАНО В
  1. Matsubara Takeshi, Mizutani Jun, Fukuoka Muneyoshi, Hatoh Tsunetoshi, Kojima Hiroshi, Otsuka Takanobu, Safe Atlantoaxial Fixation Using a Laminar Screw (Intralaminar Screw) in a Patient With Unilateral Occlusion of Vertebral Artery, Spine, 32, 1, 2007. Crossref

  2. Hue Yun Hee, Chun Hyoung-Joon, Yi Hyeong-Joong, Oh Seong Hoon, Oh Suck Jun, Ko Yong, Unilateral Posterior Atlantoaxial Transarticular Screw Fixation in Patients with Atlantoaxial Instability : Comparison with Bilateral Method, Journal of Korean Neurosurgical Society, 45, 3, 2009. Crossref

  3. Brockmeyer Douglas L., Lateral mass screw fixation of C-1, Journal of Neurosurgery: Pediatrics, 107, 2, 2007. Crossref

  4. Anderson Richard C. E., Ragel Brian T., Mocco J, Bohman Leif-Erik, Brockmeyer Douglas L., Selection of a rigid internal fixation construct for stabilization at the craniovertebral junction in pediatric patients, Journal of Neurosurgery: Pediatrics, 107, 1, 2007. Crossref

  5. Guo Qunfeng, Liu Jun, Ni Bin, Lu Xuhua, Zhou Fengjin, C2 laminar screw and C1-2 transarticular screw combined with C1 laminar hooks for atlantoaxial instability with unilateral vertebral artery injury, Archives of Orthopaedic and Trauma Surgery, 131, 9, 2011. Crossref

  6. Wright Neill M., Translaminar rigid screw fixation of the axis, Journal of Neurosurgery: Spine, 3, 5, 2005. Crossref

  7. Claybrooks Roderick, Kayanja Mark, Milks Ryan, Benzel Edward, Atlantoaxial fusion: a biomechanical analysis of two C1–C2 fusion techniques, The Spine Journal, 7, 6, 2007. Crossref

  8. Mazur Marcus D., Ravindra Vijay M., Brockmeyer Douglas L., Unilateral fixation for treatment of occipitocervical instability in children with congenital vertebral anomalies of the craniocervical junction, Neurosurgical Focus, 38, 4, 2015. Crossref

  9. TAKAYASU Masakazu, AOYAMA Masahiro, JOKO Masahiro, TAKEUCHI Mikinobu, Surgical Intervention for Instability of the Craniovertebral Junction, Neurologia medico-chirurgica, 56, 8, 2016. Crossref

  10. Bhatia Nitin, Rama Asheen, Sievers Brandon, Quigley Ryan, McGarry Michelle H., Lee Yu-Po, Lee Thay Q, Biomechanical Evaluation of Unilateral Versus Bilateral C1 Lateral Mass-C2 Intralaminar Fixation, Global Spine Journal, 7, 3, 2017. Crossref

  11. Liu Shichang, Song Zongrang, Liu Limin, Yin Xinhua, Hu Xiongke, Yang Ming, Wu Qining, Song Yueming, Hao Dingjun, Biomechanical evaluation of C1 lateral mass and C2 translaminar bicortical screws in atlantoaxial fixation: an in vitro human cadaveric study, The Spine Journal, 18, 4, 2018. Crossref

  12. Rocha Rogério, Sawa Anna G.U., Baek Seungwon, Safavi-Abbasi Sam, Hattendorf Fadimatou, Sonntag Volker K.H., Crawford Neil R., ATLANTOAXIAL ROTATORY SUBLUXATION WITH LIGAMENTOUS DISRUPTION, Operative Neurosurgery, 64, 3, 2009. Crossref

  13. Horn Eric M., Hott Jonathan S., Porter Randall W., Theodore Nicholas, Papadopoulos Stephen M., Sonntag Volker K. H., Atlantoaxial stabilization with the use of C1–3 lateral mass screw fixation, Journal of Neurosurgery: Spine, 5, 2, 2006. Crossref

  14. Chittiboina Prashant, Wylen Esther, Ogden Alan, Mukherjee Debi P., Vannemreddy Prasad, Nanda Anil, Traumatic spondylolisthesis of the axis: a biomechanical comparison of clinically relevant anterior and posterior fusion techniques, Journal of Neurosurgery: Spine, 11, 4, 2009. Crossref

3637 Просмотры статей 12 Загрузка статей Метрики
3637 ПРОСМОТРЫ 12 ЗАГРУЗКИ 14 Crossref ЦИТАТЫ Google
Scholar
ЦИТАТЫ

Статьи с похожим содержанием:

Long-Term Results of Anterior Cruciate Ligament Reconstruction Using Semitendinosus and Gracilis Tendons with Kennedy Ligament Augmentation Device Compared with Patellar Tendon Autografts Journal of Long-Term Effects of Medical Implants, Vol.10, 2000, issue 4
Yoshio Kumagae, Keishi Marumo, Takaaki Tanaka, Katsuyuki Fujii
A Cost-Effective Technique for Spinal Instrumentation in the Treatment of Adolescent Idiopathic Scoliosis Journal of Long-Term Effects of Medical Implants, Vol.26, 2016, issue 2
Styles L. Bertrand, Jonathan Pellet, David M. Cearley, Michael A. Clark, Steven J. Cowart
Isokinetic Assessment of the Knee of Amateur Soccer and Amateur Rugby Players Critical Reviews™ in Physical and Rehabilitation Medicine, Vol.31, 2019, issue 4
Youness Abdelfettah, Davelle Doungou Ngandzali, Kassimi El Hassan, Hasna Ouazzani, Brahim Erouam
Follow-up Study of Gore-Tex® Artificial Ligament—Special Emphasis on Tunnel Osteolysis Journal of Long-Term Effects of Medical Implants, Vol.10, 2000, issue 4
Toru Fukubayashi, Kohtaro Ikeda
Long-Term Clinical Review (10-20 Years) after Reconstruction of the Anterior Cruciate Ligament Using the Leeds-Keio Synthetic Ligament Journal of Long-Term Effects of Medical Implants, Vol.17, 2007, issue 1
Graham Sefton, Sameh Sidhom, Alex P. Jones

Статьи, принятые к публикации

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Портал Begell Электронная Бибилиотека e-Книги Журналы Справочники и Сборники статей Коллекции Цены и условия подписки Begell House Контакты Language English 中文 Русский Português German French Spain