DOI: 10.1615/JLongTermEffMedImplants.v20.i1.60
pages 43-48

Evidence That In Vivo Wear Damage Alters Kinematics and Contact Stresses in a Total Knee Replacement

John L. Williams
University of Memphis, Department of Biomedical Engineering; InMotion Orthopaedic Research Center, Memphis TN, USA
David A. Knox
University of Memphis, Memphis, TN
Matthew G Teeter
Division of Orthopaedic Surgery, London Health Sciences Centre, London, Ontario, N6A 5A5, Canada
David W. Holdsworth
Imaging Research Laboratories, Robarts Research Institute; Department of Medical Biophysics; Division of Orthopaedic Surgery, The University of Western Ontario
William M. Mihalko
Department of Orthopaedic Surgery and Biomedical Engineering, School of Medicine, University of Tennessee Health Science Center, Memphis TN; Campbell Clinic Orthopedics, Germantown, TN

Краткое описание

Polyethylene wear after a total knee arthroplasty is inevitable. The effects of the wear particles on the surrounding soft tissue causing inflammatory responses and eventual aseptic loosening are well documented, but the biomechanical changes from polyethylene wear have been less understood. This study investigated how wear from a retrieved polyethylene insert from a total knee arthroplasty changed the kinematics and contact stresses. A cruciate-retaining total knee implant (Natural-Knee, Intermedics Orthopedics, Inc., Austin, Texas) was retrieved from a donor program. The polyethylene insert was then scanned and modeled. KneeSIM (LifeMOD/KneeSIM, San Clemente, California) was used to simulate one cycle of gait of three second duration (100% of cycle). A threefold increase in contact stress as well as resulting kinematic changes were seen when the model was used to compare the retrieved versus a modeled off-the-shelf new polyethylene insert. Total knee designs should take into account the wear patterns that result from years of use and how they may affect the biomechanics of the knee long term.

Ключевые слова: knee, arthroplasty, wear, retrieval, biomechanics

Articles with similar content:

Patellar Button Wear Patterns in Well-Functioning Total Knee Arthroplasty Retrievals
Journal of Long-Term Effects of Medical Implants, Vol.20, 2010, issue 1
John L. Williams, Devin Conner, Peter Godleski, Brian Perkinson, Jason A. Lindsey, William M. Mihalko
Preface to Special Section: Retrieval Analysis of Implanted Medical Devices
Journal of Long-Term Effects of Medical Implants, Vol.20, 2010, issue 1
William M. Mihalko
Comparison of Total Body Tissue Interface Pressure of Specialized Pressure-Relieving Mattresses
Journal of Long-Term Effects of Medical Implants, Vol.14, 2004, issue 2
Robert Duncan, William L. Hickerson, George M. Slugocki, Reuben L. Thaker, John F. Bishop, Judy K. Parks
Failure of a Medial Unicompartmental Knee Replacement due to Metal Allergy
Journal of Long-Term Effects of Medical Implants, Vol.28, 2018, issue 4
Shamsul Khan, Theodore Balfousias, George Tselentakis, Bala Srikanth, Alexandros P. Apostolopoulos
Eosinophilic Metallosis: A Newly Described Entity in Failed Metal-on-Metal Arthroplasty
Journal of Long-Term Effects of Medical Implants, Vol.26, 2016, issue 4
A. Hanflik, E. Bryk, Brandon Levy, Vincent J. Vigorita