Доступ предоставлен для: Guest
Портал Begell Электронная Бибилиотека e-Книги Журналы Справочники и Сборники статей Коллекции
Heat Transfer Research
Импакт фактор: 0.404 5-летний Импакт фактор: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Печать: 1064-2285
ISSN Онлайн: 2162-6561

Выпуски:
Том 51, 2020 Том 50, 2019 Том 49, 2018 Том 48, 2017 Том 47, 2016 Том 46, 2015 Том 45, 2014 Том 44, 2013 Том 43, 2012 Том 42, 2011 Том 41, 2010 Том 40, 2009 Том 39, 2008 Том 38, 2007 Том 37, 2006 Том 36, 2005 Том 35, 2004 Том 34, 2003 Том 33, 2002 Том 32, 2001 Том 31, 2000 Том 30, 1999 Том 29, 1998 Том 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.v42.i7.30
pages 629-643

Interfacial Shear of Co-Current Steam−Water Flow Estimation − I. Single-Phase FLUENT Model in Conjunction with Measured Total Increment of Water Temperature and Steam Velocity Profile Data

Stasys Gasiunas
Lithuanian Energy Institute, 3 Breslaujos str., LT-3035 Kaunas, Lithuania
Marijus Seporaitis
Lithuanian Energy Institute, 3 Breslaujos g., Kaunas, LITHUANIA, LT-44403
Benediktas B. Cesna
Lithuanian Energy Institute, Kaunas, Lithuania
Mindaugas Valincius
Lithuanian Energy Institute, 3 Breslaujos str., LT-3035 Kaunas, Lithuania
Raimondas Pabarcius
Lithuanian Energy Institute, 3 Breslaujos str., LT-3035 Kaunas, Lithuania
Darius Laurinavicius
Lithuanian Energy Institute, Kaunas, Lithuania

Краткое описание

The results of condensation implosion tests (Almenas et al., 2006) and slug flow occurrence (Chun and Yu, 2000) lead to the conclusion that condensation may have some serious impact on steam−liquid interface stability. To explore this in detail a special test facility was constructed and the FLUENT 3D model (single phase with condensation simulation) is developed at the Lithuanian Energy Institute. The following investigation seeks to determine the condensation influence on the stability of a horizontal two-phase flow interface, and the overall purpose of the program is to employ transitional behaviors with positive feedback between momentum and energy transfer in real systems. This paper presents the LEI experimental test facility and methodology of the experiments whose results were employed to adopt and verify the FLUENT 3D model. Preliminary simulation results show that the boundary layer thickness and also interfacial shear strongly depend on condensation.


Articles with similar content:

INTERFACIAL SHEAR OF CO-CURRENT STEAM−WATER FLOW ESTIMATION − II. ENHANCED SINGLE-PHASE FLUENT MODEL IN CONJUNCTION WITH MEASURED PROFILES OF STEAM VELOCITY AND LONGITUDINAL WATER TEMPERATURE
Heat Transfer Research, Vol.43, 2012, issue 5
Benediktas B. Cesna, Darius Laurinavicius, Stasys Gasiunas, Mindaugas Valincius, Marijus Seporaitis, Raimondas Pabarcius
NUMERICAL SIMULATION of STEAM DIRECT CONTACT CONDENSATION
International Heat Transfer Conference 16, Vol.6, 2018, issue
A. Yuanshu Lu, B. Tao Lu, Bo Liu, C. Yuanyuan Li
NUMERICAL MODELING OF THE POSITION OF A LAMINAR-TURBULENT TRANSITION ON A WING WITH THE LAMINAR AIRFOIL LV6
TsAGI Science Journal, Vol.44, 2013, issue 1
Sergei Leonidovich Chernyshev, Andrey Filippovich Kiselev, Valery Viktorovich Vozhdaev, Leonid Leonidovich Teperin, Dmitry Sergeevich Sboev
4.9 The Physical Model of Lean Suppression Pressure Oscillation Phenomena: Steam Condensation in the Light Water Reactor Pressure Suppression System
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 1980, issue
Eckhardt Aust, Jurgen Vollbrandt, Garry S. Holman, Edward W. McCauley, Henning Schwan
Two-Phase Flow with Phase Transitions Instability
Heat Transfer Research, Vol.28, 1997, issue 4-6
B. V. Kichatov, I. V. Boyko