Доступ предоставлен для: Guest
Портал Begell Электронная Бибилиотека e-Книги Журналы Справочники и Сборники статей Коллекции
Heat Transfer Research
Импакт фактор: 0.404 5-летний Импакт фактор: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Печать: 1064-2285
ISSN Онлайн: 2162-6561

Выпуски:
Том 50, 2019 Том 49, 2018 Том 48, 2017 Том 47, 2016 Том 46, 2015 Том 45, 2014 Том 44, 2013 Том 43, 2012 Том 42, 2011 Том 41, 2010 Том 40, 2009 Том 39, 2008 Том 38, 2007 Том 37, 2006 Том 36, 2005 Том 35, 2004 Том 34, 2003 Том 33, 2002 Том 32, 2001 Том 31, 2000 Том 30, 1999 Том 29, 1998 Том 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2018021203
pages 1-16

ANALYSES OF ENTRANSY DISSIPATION RATIO AND ENTROPY GENERATION RATIO FOR GAS POWER CYCLES UNDER VARIOUS CONDITIONS: EDEG SOFTWARE

Ankur Geete
Mechanical Engineering Department, Sushila Devi Bansal College of Technology, Indore, Madhya Pradesh, 453331, India

Краткое описание

Gas power plants are based on a gas power cycle with two constant pressure processes and two isentropic processes. In this paper, a thermodynamic analysis of a gas power plant is made. Entransy dissipation analysis and entropy generation analysis are made under various operating conditions, that is: at different specific heats of fluids, different numbers of transfer units, and different isentropic efficiencies for the turbine and compressor. In this work, the entransy dissipation-entropy generation (EDEG) software has been developed which is used to analyze the effectiveness, entransy dissipation, entropy generation, entransy dissipation ratio, and entropy generation ratio for the cycle under different operating conditions. The EDEG software is also used to generate different performance characteristic curves of various parameters. These curves help to identify that optimum conditions at which both entropy generation and entransy dissipation are minimum. The conclusions of this research work are: (a) when Cp is 0.5 kJ/kg K, the effectiveness for hot and cold fluids is maximum and equal to 0.973 and 0.970, respectively, and the entransy dissipation ratio is 1.836 which is also maximum; (b) when Ch and Cc are 5.0 and 4.0 kJ/kg K, respectively, the effectiveness for hot and cold fluids is maximum and equal to 0.967 and 0.962, respectively, but EGr and EDr are minimum — 0.84 and 0.961, respectively; (c) when NTUs for hot and cold fluids are 5, the effectiveness for hot and cold fluids is maximum and equal to 0.982 and 0.976, respectively, and (d) when ηcom and ηtur are 75% and 85%, respectively, the EGr and EDr are maximum and equal to 1.217 and 1.817, respectively.


Articles with similar content:

NOx EMISSION MODELS SUITABLE FOR OPERATION AND CONTROL OF POWER GENERATION BOILERS
International Journal of Energy for a Clean Environment, Vol.5, 2004, issue 1
Steve Thompson, Kang Li
THERMODYNAMIC ANALYSIS AND SENSITIVITY STUDIES ON BRAYSSON CYCLE USING AN INTELLIGENT CAI SOFTWARE
Proceedings of Symposium on Energy Engineering in the 21st Century (SEE2000) Volume I-IV, Vol.0, 2000, issue
Souvik Bhattacharyya
CHARACTERISTICS OF WATER DROPLET IMPACTION BEHAVIOR ON A POLISHED STEEL HEATED SURFACE: Part II
Atomization and Sprays, Vol.17, 2007, issue 8
Ghasem G. Nasr, Andrew J. Yule, S. W. Akhtar
EFFECT OF THE REACTOR CHARACTERISTICS ON THE PERFORMANCE OF A CHEMISORPTION REFRIGERATOR USING AN SrCl2 COMPOSITE SORBENT
Heat Transfer Research, Vol.46, 2015, issue 2
Rogerio Oliveira, C.J.N. Sanchez, Sergio Colle
Thermodynamic Analysis to Assist in the Design of Recombinant Antibodies
Critical Reviews™ in Immunology, Vol.32, 2012, issue 6
Eric T. Mack, Paul J. Bracher, Raquel Perez-Castillejos