Доступ предоставлен для: Guest
Портал Begell Электронная Бибилиотека e-Книги Журналы Справочники и Сборники статей Коллекции
Journal of Porous Media
Импакт фактор: 1.752 5-летний Импакт фактор: 1.487 SJR: 0.43 SNIP: 0.762 CiteScore™: 2.3

ISSN Печать: 1091-028X
ISSN Онлайн: 1934-0508

Выпуски:
Том 23, 2020 Том 22, 2019 Том 21, 2018 Том 20, 2017 Том 19, 2016 Том 18, 2015 Том 17, 2014 Том 16, 2013 Том 15, 2012 Том 14, 2011 Том 13, 2010 Том 12, 2009 Том 11, 2008 Том 10, 2007 Том 9, 2006 Том 8, 2005 Том 7, 2004 Том 6, 2003 Том 5, 2002 Том 4, 2001 Том 3, 2000 Том 2, 1999 Том 1, 1998

Journal of Porous Media

DOI: 10.1615/JPorMedia.v13.i7.50
pages 637-643

EXPERIMENTAL QUANTIFICATION OF THE OPERATIVE TIME OF A PASSIVE HVAC SYSTEM USING POROUS COVERING MATERIALS

José A. Orosa
Department of Energy, University of Coruña, Spain
Armando C. Oliveira
New Energy Technology Unit, Faculdade de Engenharia, Universidade do Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
Nuno M. M. Ramos
Laboratório de Física das Construções (LFC), Departamento de Engenharia Civil, Universidade do Porto

Краткое описание

Permeable coverings are porous materials that improve partial vapor pressure and thereby the agreeable nature of the indoor environment and local thermal comfort, while also saving energy. This is a consequence of the damping effect of materials on air humidity and is determined by the rate at which real buildings absorb moisture. This rate cannot be predicted using sorption isotherm data and has to be obtained experimentally. A new experimental method to obtain the real storage capacity and rate of sorption of covering materials is presented. A significance analysis showed that permeable coverings have an effect in indoor air conditions, not only during the first hours of occupation but also throughout the day. The maximum effect occurs during the early period (between 0900 LT and 1400 LT) and includes the 4-hour period after the office is closed. The results show that the sorption of water vapor in the porous envelope has a greater effect on indoor humidity than ventilating the room with 0.5 ach.


Articles with similar content:

Effects of Exfiltration on Moisture and Frost Accumulation in a Fibrous Insulation
International Journal of Fluid Mechanics Research, Vol.25, 1998, issue 4-6
D. R. Mitchell, Y. -X. Tao, Robert W. Besant
STUDY OF COUPLED HEAT AND MOISTURE TRANSFER WITHIN A VEGETAL FIBRE MATERIAL FOR BUILDING ENVELOPE
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2012, issue
Ton Hoang Mai, Etienne Wurtz, Chadi Maalouf, Mohammed Lachi
POLYNOMIAL APPROXIMATION OF MOISTURE STORAGE FUNCTION OF CONCRETE FOR USE IN HYGROTHERMAL ANALYSES OF BUILDING COMPONENTS−METHOD AND COMPUTATIONAL TOOL
Special Topics & Reviews in Porous Media: An International Journal, Vol.5, 2014, issue 3
Dimitris Aravantinos, Christina Giarma
Variation of the Medium State in a Hypobaric Storehouse
Heat Transfer Research, Vol.28, 1997, issue 7-8
E. Pisarev
Water Vapor Transfer through Textile under a Temperature and Humidity Gradient
Journal of Porous Media, Vol.7, 2004, issue 2
Sassi Ben Nasrallah, Nada Nefzi, Moez Jouini