Доступ предоставлен для: Guest
Портал Begell Электронная Бибилиотека e-Книги Журналы Справочники и Сборники статей Коллекции
Journal of Porous Media
Импакт фактор: 1.49 5-летний Импакт фактор: 1.159 SJR: 0.43 SNIP: 0.671 CiteScore™: 1.58

ISSN Печать: 1091-028X
ISSN Онлайн: 1934-0508

Выпуски:
Том 22, 2019 Том 21, 2018 Том 20, 2017 Том 19, 2016 Том 18, 2015 Том 17, 2014 Том 16, 2013 Том 15, 2012 Том 14, 2011 Том 13, 2010 Том 12, 2009 Том 11, 2008 Том 10, 2007 Том 9, 2006 Том 8, 2005 Том 7, 2004 Том 6, 2003 Том 5, 2002 Том 4, 2001 Том 3, 2000 Том 2, 1999 Том 1, 1998

Journal of Porous Media

DOI: 10.1615/JPorMedia.v15.i8.10
pages 705-720

COMPARISON OF TWO PERMEATION TEST BENCHES AND TWO DETERMINATION METHODS FOR DARCY'S AND FORCHHEIMER'S PERMEABILITIES

Nicolas Gascoin
PRISME Laboratory, INSA-Centre Val de Loire, 88 boulevard Lahitolle, 18000 Bourges, France
Guillaume Fau
PRISME Laboratory, INSA-Centre Val de Loire, 88 boulevard Lahitolle, 18000 Bourges, France
Philippe Gillard
PRISME, IUT Bourges, 63, avenue de Lattre de Tassigny, 18000 Bourges, France
Markus Kuhn
German Aerospace Center, Pfaffenwaldring 38-40, 70569 Stuttgart, Germany
Marc Bouchez
MBDA-France, 18 rue Le Brix, 18000 Bourges, France
Johan Steelant
The European Space Research and Technology Center, Noordwijk, Netherlands

Краткое описание

The thermal load protection of hypersonic and space vehicle structures can be achieved by either passive or active methods, such as ablative materials or active cooling. For the latter, porous Ceramic Matrix Composite media offer a possibility to exploit thermal protection by means of transpiration cooling. One of the related key issues is the estimation of permeability parameters such as Darcy's and Forchheimer's terms. The present paper aims at proposing an analytical and applied comparison of two determination methods (one based on the International Standard Organisation (ISO) norm 4022 and one derived for compressible flows, the so-called P 2 method). To apply these mathematically equivalent laws, a cross verification and validation has been carried out on two different test rigs with different porous media (metallic and composite) with a range of Darcian permeability varying from 10−17 m 2 to 10−11 m 2. The French PRISME laboratory test bench has a higher accuracy for thin samples (under 3 mm), while the German Aerospace Center (DLR) rig is more adapted to thick samples (over 3 mm). The results are judged to be satisfactory (discrepancy around 14% for reference samples). The methods used to post-process the data can generate discrepancies up to a factor of2 for a given set of experimental data.


Articles with similar content:

BENCHMARK SUMMARY OF NUMERICAL STUDIES: 3-D NATURAL CONVECTION IN AN AIR-FILLED ENCLOSURE
ICHMT DIGITAL LIBRARY ONLINE, Vol.4, 2001, issue
K. G. Terry Hollands, Darrell W. Pepper
Determination of the Overall Yield Strength Domain of Out-of-Plane Loaded Brick Masonry
International Journal for Multiscale Computational Engineering, Vol.5, 2007, issue 2
Karam Sab, Julien Dallot, Antonella Cecchi
NUMERICAL SIMULATION OF THE NATURAL CONVECTIVE FLOW FOR ELECTRONICS PACKAGING APPLICATION
ICHMT DIGITAL LIBRARY ONLINE, Vol.13, 2008, issue
Florence Michel, Heinrich Reister, Bernard Desmet
COUPLED TEMPERATURE AND VELOCITY MEASUREMENTS AND USE OF THE POD FOR THE ESTIMATION OF TURBULENT HEAT FLUXES IN A DIFFERENTIALLY HEATED CAVITY
First Thermal and Fluids Engineering Summer Conference, Vol.7, 2015, issue
Didier Saury, Denis Lemonnier, Pierre Belleoud
EXPERIMENTAL AND THEORETICAL DETERMINATION OF SPECTRAL HEAT FLUX EMITTED BY A CERAMIC UNDER AXIAL TEMPERATURE GRADIENT
International Heat Transfer Conference 13, Vol.0, 2006, issue
V. Ducamp, Agnes Delmas, F. Oelhoffen, L. Robin, T. Lanternier