Доступ предоставлен для: Guest
Портал Begell Электронная Бибилиотека e-Книги Журналы Справочники и Сборники статей Коллекции
Journal of Enhanced Heat Transfer
Импакт фактор: 0.562 5-летний Импакт фактор: 0.605 SJR: 0.175 SNIP: 0.361 CiteScore™: 0.33

ISSN Печать: 1065-5131
ISSN Онлайн: 1026-5511

Выпуски:
Том 27, 2020 Том 26, 2019 Том 25, 2018 Том 24, 2017 Том 23, 2016 Том 22, 2015 Том 21, 2014 Том 20, 2013 Том 19, 2012 Том 18, 2011 Том 17, 2010 Том 16, 2009 Том 15, 2008 Том 14, 2007 Том 13, 2006 Том 12, 2005 Том 11, 2004 Том 10, 2003 Том 9, 2002 Том 8, 2001 Том 7, 2000 Том 6, 1999 Том 5, 1998 Том 4, 1997 Том 3, 1996 Том 2, 1995 Том 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.2015015645
pages 121-145

A CASE STUDY OF USING ENHANCED INTERCONNECT CHANNEL GEOMETRIES ON HEAT AND MASS TRANSFER CHARACTERISTICS OF ANODE-SUPPORTED PLANAR SOFC

Yogesh N. Magar
Thermal-Fluids & Thermal Processing Laboratory, Department of Mechanical and Materials Engineering, University of Cincinnati, Cincinnati, OH 45221-0072
Raj M. Manglik
Thermal-Fluids and Thermal Processing Laboratory, Mechanical and Materials Engineering, University of Cincinnati, 2600 Clifton Ave, Cincinnati, OH 45220, USA

Краткое описание

The role of enhanced heat transfer inside interconnect channels for improved convective cooling and thermal management of planar solid oxide fuel cells (SOFCs) is investigated. A case study of two different geometries (sinusoidal wavy or corrugated walls and offset-and- interrupted walls) is presented for a uniform electrochemical reaction rate with constant flow of moist hydrogen and air. The coupled heat and mass transfer is modeled by three-dimensional, steady-state equations for mass, momentum, energy, species transfer, and electrochemical kinetics, in which the porous-layer flow is in thermal equilibrium with the solid matrix and is coupled with the electrochemical reaction rate. The heat and mass transfer rates through the interconnect ducts as well as the electrodes on both the anode and cathode sides are computationally obtained. The temperature field and species mass distributions, along with variations in the friction factor and heat transfer coefficients describe the performance of the two flow-channel geometries. The relative thermal and hydrodynamic behavior is compared with that in plain rectangular-duct interconnects to evaluate their convective-cooling performance. The results demonstrate that the offset interrupted-wall geometry yields better cooling of the SOFC module.


Articles with similar content:

Multiscale Assessment of Charge and Mass Transfer in Solid Oxide Cells
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2015, issue
George J. Nelson
NUMERICAL SIMULATION OF FILM CONDENSATION FROM GAS–VAPOR MIXTURES IN VERTICAL PARALLEL PLATE CHANNELS
Computational Thermal Sciences: An International Journal, Vol.10, 2018, issue 4
Scott J. Ormiston, Foad Hassaninejadfarahani
NUMERICAL INVESTIGATION OF SPECIES DISTRIBUTION AND THE ANODE TRANSFER COEFFICIENT EFFECT ON THE PROTON EXCHANGE MEMBRANE FUEL CELL (PEMFC) PERFORMANCE
Heat Transfer Research, Vol.46, 2015, issue 10
Sajad Rezazadeh, Vahid Ahmadpour, Nima Ahmadi
NUMERICAL ANALYSIS OF LAMINAR HEAT TRANSFER AND FLUID FLOW IN A FLAT TUBE PARTIALLY FILLED WITH A POROUS MATERIAL
Journal of Porous Media, Vol.21, 2018, issue 12
Abbas Abbassi, Ehsan Rezaei, Hamed Safikhani
Multiscale Modeling Approaches of Transport Phenomena in Fuel Cells
International Heat Transfer Conference 15, Vol.1, 2014, issue
Bengt Sunden