Доступ предоставлен для: Guest
Портал Begell Электронная Бибилиотека e-Книги Журналы Справочники и Сборники статей Коллекции
Journal of Enhanced Heat Transfer
Импакт фактор: 1.406 5-летний Импакт фактор: 1.075 SJR: 0.287 SNIP: 0.653 CiteScore™: 1.2

ISSN Печать: 1065-5131
ISSN Онлайн: 1563-5074

Выпуски:
Том 27, 2020 Том 26, 2019 Том 25, 2018 Том 24, 2017 Том 23, 2016 Том 22, 2015 Том 21, 2014 Том 20, 2013 Том 19, 2012 Том 18, 2011 Том 17, 2010 Том 16, 2009 Том 15, 2008 Том 14, 2007 Том 13, 2006 Том 12, 2005 Том 11, 2004 Том 10, 2003 Том 9, 2002 Том 8, 2001 Том 7, 2000 Том 6, 1999 Том 5, 1998 Том 4, 1997 Том 3, 1996 Том 2, 1995 Том 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.v11.i4.190
pages 417-422

Experimental Investigation on Fouling Performance of Corrugated Tubes

Zhi-ming Xu
College of Energy and Power Engineering, Northeast Electric Power University, 169 Chang Chun Rd. Chuanying District, Jilin 132012, China
Shanrang Yang
Northeast China Institute of Electric Power Engineering, Jilin City, Jilin Province, 132012, China
Yunhua Gan
Northeast China Institute of Electric Power Engineering, Jilin City, Jilin Province, 132012, China

Краткое описание

This paper describes the results of heat transfer performance tests for cooling water flowing inside the corrugated tube. Based on the experimental data, a dimensionless correlation for forced convection heat transfer inside the corrugated tube is attained. Moreover, the comparative fouling experiments were carried out between a corrugated tube and its corresponding plain tube. The experimental working fluid was water solution of CaCl2 and NaHCO3 with a hardness of 800 mg/L inside tubes, and the experiments were done under the conditions of 0.38 m/s liquid velocity, temperature of 60 °C at the water tank, and the same inlet temperature of working fluid inside the tubes. The experimental results show that the corrugated tube has an advantage both in heat transfer performance and in anti-fouling ability over the plain tube.


Articles with similar content:

ANALYSIS OF COOLING TOWER FOULING IN ENHANCED TUBES BASED ON THE PRANDTL ANALOGY
Journal of Enhanced Heat Transfer, Vol.18, 2011, issue 6
Guan-Qiu Li, Zheng-Jiang Zhang, Wei Li, Zhi-Ke Wang, Zhi-ming Xu
AERODYNAMIC AND HEAT TRANSFER PERFORMANCE OF AN INDUSTRIAL AIR-COOLED HEAT EXCHANGER
International Heat Transfer Conference 5, Vol.9, 1974, issue
R. A. Stinchcombe, G. H. Cowan, F. R. Dell
A STUDY ON THE HIGH PERFORMANCE CERAMIC HEAT EXCHANGER FOR ULTRA HIGH TEMPERATURES
International Heat Transfer Conference 11, Vol.16, 1998, issue
Masaya Kumada, Yuji Himeji
PERFORMANCE OF AN INDUSTRIAL AIR-COOLED HEAT EXCHANGER WITH CONTROLLED AIR RECIRCULATION
International Heat Transfer Conference 7, Vol.15, 1982, issue
D.J. Wilson, R. A. Stinchcombe, G. H. Cowan
EVAPORATOR USING HEAT PIPE HEAT EXCHANGER FOR A HEAT RECOVERY SYSTEM
Heat Pipe Science and Technology, An International Journal, Vol.5, 2014, issue 1-4
F. Chejne J., L. A. Betancur A.