Том 27, 2020 Том 26, 2019 Том 25, 2018 Том 24, 2017 Том 23, 2016 Том 22, 2015 Том 21, 2014 Том 20, 2013 Том 19, 2012 Том 18, 2011 Том 17, 2010 Том 16, 2009 Том 15, 2008 Том 14, 2007 Том 13, 2006 Том 12, 2005 Том 11, 2004 Том 10, 2003 Том 9, 2002 Том 8, 2001 Том 7, 2000 Том 6, 1999 Том 5, 1998 Том 4, 1997 Том 3, 1996 Том 2, 1995 Том 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.2013006759
pages 225-233

EXPERIMENTAL INVESTIGATION ON FLOW PATTERNS AND PRESSURE DROP OF R134A FLOW BOILING IN A HORIZONTAL HELICALLY COILED PIPE

L. Shao
School of Energy and Power Engineering, Shandong University, Jinan 250061, P. R. China
Jitian Han
School of Energy and Power Engineering, Shandong University, Jinan, Shandong Province 250061, China
M. X. Wang
School of Energy and Power Engineering, Shandong University, Jinan 250061, P. R. China
Changnian Chen
School of Energy and Power Engineering, Shandong University, Jinan, Shandong Province 250061, China
T. C. Jen
Department of Mechanical Engineering, University of Alaska Anchorage, Anchorage, AK 99508, USA

Краткое описание

Experiments were performed to investigate the characteristics of flow boiling patterns and pressure drops of R134a in a horizontal helically coiled pipe. The test section is made of a 7.6 mm inner diameter and 10 mm outer diameter stainless steel tube, the structural parameters of which are eight coils, 300 mm coil diameter, and 30 mm pitch, which was heated directly by low-voltage and high-current direct current power supplies. The experiments were carried out under the conditions of saturation temperatures ranging from 5° to 20° refrigerant mass fluxes varying from 50 to 500 kgm−2s−1, heat fluxes varying from 5 to 20 kWm−2, and vapor qualities ranging from 0.01 to 0.9. The flow patterns were obtained through visualization experiments, and it was found that the flow patterns in the rising and declining sections of the horizontal helically coiled test pipe were somehow different under the same conditions, especially in the case of the observation of two new transition flow patterns that occurred before the formation of the annular flow; i.e., wave annular flow and super slug flow. Therefore, two different flow pattern figures have been proposed for the rising and declining sections according to different situations. The flow frictional pressure drops were experimentally determined and a new correlation has been developed to predict the flow frictional factors through the regression analysis of the experimental data.


Articles with similar content:

PRESSURE DROP IN R-245FA CONDENSATION IN TUBES FITTED WITH COILED-WIRE INSERTS
Journal of Enhanced Heat Transfer, Vol.21, 2014, issue 6
AJIT KHATUA, Hari Narayan Singh, Parmanand Kumar
Heat Transfer Coefficient and Pressure Drop Characteristics during R-1234yf Evaporation Inside Horizontal Small Tubes
International Heat Transfer Conference 15, Vol.16, 2014, issue
Pham Quang Vu, Nguyen Ba Chien, Jong-Taek Oh, Kwang-Il Choi
HEAT TRANSFER AND PRESSURE DROP CHARACTERISTICS IN THE TRANSITIONAL FLOW REGIME OF TWISTED TAPE INSERT IN A CIRCULAR TUBE WITH RE-ENTRANT INLET
International Heat Transfer Conference 16, Vol.13, 2018, issue
Josua Petrus Meyer, Sogo Mayokun Abolarin
EXPERIMENTAL INVESTIGATION OF CONVECTIVE HEAT TRANSFER IN THE TRANSITIONAL FLOW REGIME OF AN INCLINED SMOOTH TUBE
International Heat Transfer Conference 16, Vol.9, 2018, issue
Josua Petrus Meyer, Abubakar Idris Bashir
HEAT TRANSFER AND PRESSURE DROP DURING EVAPORATION AND CONDENSATION OF R134a INSIDE TWO MICROFIN TUBES OF NEW DESIGN
International Heat Transfer Conference 13, Vol.0, 2006, issue
Alfonso Niro, Andrea Lucchini, Luigi Pietro Maria Colombo, Adriano Muzzio