Доступ предоставлен для: Guest
Портал Begell Электронная Бибилиотека e-Книги Журналы Справочники и Сборники статей Коллекции
Atomization and Sprays
Импакт фактор: 1.737 5-летний Импакт фактор: 1.518 SJR: 0.814 SNIP: 1.18 CiteScore™: 2.2

ISSN Печать: 1044-5110
ISSN Онлайн: 1936-2684

Выпуски:
Том 30, 2020 Том 29, 2019 Том 28, 2018 Том 27, 2017 Том 26, 2016 Том 25, 2015 Том 24, 2014 Том 23, 2013 Том 22, 2012 Том 21, 2011 Том 20, 2010 Том 19, 2009 Том 18, 2008 Том 17, 2007 Том 16, 2006 Том 15, 2005 Том 14, 2004 Том 13, 2003 Том 12, 2002 Том 11, 2001 Том 10, 2000 Том 9, 1999 Том 8, 1998 Том 7, 1997 Том 6, 1996 Том 5, 1995 Том 4, 1994 Том 3, 1993 Том 2, 1992 Том 1, 1991

Atomization and Sprays

DOI: 10.1615/AtomizSpr.2015010736
pages 571-586

SIMULATION OF THE CALCIUM CHLORIDE AQUEOUS SALT SOLUTION SPRAY REGENERATION PROCESS

Y. A. F. EL-Samadony
Mechanical Power Engineering Department, Faculty of Engineering, Tanta University, Egypt
Bernard M. Gibbs
Energy and Resources Research Institute, Houldsworth Building, University of Leeds, Leeds LS2 9JT, UK
W. Nimmo
Energy and Resources Research Institute, Houldsworth Building, University of Leeds, Leeds LS2 9JT, UK

Краткое описание

The present work is a simulation of spray regeneration of liquid desiccant aqueous solution using three-dimensional computational fluid dynamic software (CFX-10). This simulation involved the spray evaporation of calcium chloride aqueous salt solution, as a liquid desiccant, into hot moist air. Liquid desiccants have a unique mass transfer direction that depends on the value of the liquid desiccant vapor pressure to air vapor pressure. Therefore, a FORTRAN subroutine was designed and added to the CFX software, which dealt with the rate of mass transfer between the desiccant liquid and the hot moist air. Additionally, the effect of the spray evaporation parameters was investigated. To validate the numerical CFX work, an experimental test rig was designed and built, and a few experimental results were obtained. It was found that the values of the injected droplet diameter size, spray angle, hot air temperature, and spray injection speed had an important role in the liquid desiccant regeneration process. Finally, the CFX software with an additional subroutine succeeded in simulating the spray evaporation of calcium chloride aqueous salt solution.


Articles with similar content:

COMPUTATIONAL FLUID DYNAMICS MODELING AND COMPUTATION OF CONVECTIVE HEAT COEFFICIENT TRANSFER FOR AUTOMOTIVE DISC BRAKE ROTORS
Computational Thermal Sciences: An International Journal, Vol.10, 2018, issue 1
ali belhocine, Wan Zaidi Wan Omar
EXPERIMENTAL INVESTIGATION ON MASS TRANSFER CHARACTERISTIC OF STABLE STEAM JET CONDENSATION IN A RECTANGULAR MIX CHAMBER
International Heat Transfer Conference 16, Vol.7, 2018, issue
Cheng-Shi Yang, Jiping Liu, Xiao Zong, Junjie Yan
Numerical Investigation of Dynamic Response of Deploying System during a Circular Cylinder Lowering through Air-Water Interface
International Journal of Fluid Mechanics Research, Vol.42, 2015, issue 3
Shaojun Liu, Xiaozhou Hu
Numerical Analysis of Air Flow and Heat Transfer in Tubular-Blown Film Processing
International Heat Transfer Conference 11, Vol.12, 1998, issue
O. AKAIKE , Yasutaka Nagano, Toshihiro Tsuji
A COMPUTER NETWORK INTRUSION DETECTION TECHNOLOGY BASED ON IMPROVED NEURAL NETWORK ALGORITHM
Telecommunications and Radio Engineering, Vol.79, 2020, issue 7
R. X. Liu