Доступ предоставлен для: Guest
Портал Begell Электронная Бибилиотека e-Книги Журналы Справочники и Сборники статей Коллекции
Atomization and Sprays

Импакт фактор: 1.235

ISSN Печать: 1044-5110
ISSN Онлайн: 1936-2684

Выпуски:
Том 27, 2017 Том 26, 2016 Том 25, 2015 Том 24, 2014 Том 23, 2013 Том 22, 2012 Том 21, 2011 Том 20, 2010 Том 19, 2009 Том 18, 2008 Том 17, 2007 Том 16, 2006 Том 15, 2005 Том 14, 2004 Том 13, 2003 Том 12, 2002 Том 11, 2001 Том 10, 2000 Том 9, 1999 Том 8, 1998 Том 7, 1997 Том 6, 1996 Том 5, 1995 Том 4, 1994 Том 3, 1993 Том 2, 1992 Том 1, 1991

Atomization and Sprays

DOI: 10.1615/AtomizSpr.v14.i3.40
24 pages

DEVELOPMENT OF AN AIR-BLAST ATOMIZER FOR INDEPENDENT CONTROL OF DROPLET SIZE AND SPRAY DENSITY

H. L. Clack
Department of Mechanical Engineering, University of California, Berkeley, Berkeley, California, USA
C. P. Koshland
School of Public Health, University of California, Berkeley, Berkeley, California, USA
D. Lucas
Lawrence Berkeley National Laboratory, University of California, Berkeley, Berkeley, California, USA
R. F. Sawyer
Department of Mechanical Engineering, University of California, Berkeley, Berkeley, California, USA

Краткое описание

The atomizer described is a novel twin-fluid design that allows independent control of mean droplet size and mean spray density. Designed to handle unpressurized fluids at low flow rates, the prefilming double-annular air-blast atomizer (PFDAAA) distributes fuel in a liquid film over a hollow, tapered cylindrical centerbody. Two independently controlled atomizing gas streams shear the inner and outer surfaces of the cylindrical fluid film at the injector tip, resulting in continuously variable atomization. Data taken during a series of cold-flow experiments include both mean droplet size and spray density measures. The data demonstrate that controlling the relative flow rates of the two atomizing gas streams produces droplet dispersions whose mean droplet size and spray density vary independently of each other. Measured values of Sauter mean diameter (SMD) for isopropyl alcohol sprays range from 250 to 3100 μm, and values of normalized interdroplet spacing range from 0.8 to 3.6 mean droplet diameters. When presented collectively, the mean droplet size and spray density data form a performance map indicating the operating range of the PFDAAA for the conditions tested. Parametrically variable sprays such as those generated by the PFDAAA constitute a previously unavailable experimental platform for spray combustion research. Investigations using laser diagnostics to probe a controlled, variable spray could provide insights into the physicochemical processes within a spray that ultimately affect combustion efficiency and pollutant formation.