Доступ предоставлен для: Guest
Портал Begell Электронная Бибилиотека e-Книги Журналы Справочники и Сборники статей Коллекции
Atomization and Sprays
Импакт фактор: 1.262 5-летний Импакт фактор: 1.518 SJR: 0.814 SNIP: 1.18 CiteScore™: 1.6

ISSN Печать: 1044-5110
ISSN Онлайн: 1936-2684

Выпуски:
Том 29, 2019 Том 28, 2018 Том 27, 2017 Том 26, 2016 Том 25, 2015 Том 24, 2014 Том 23, 2013 Том 22, 2012 Том 21, 2011 Том 20, 2010 Том 19, 2009 Том 18, 2008 Том 17, 2007 Том 16, 2006 Том 15, 2005 Том 14, 2004 Том 13, 2003 Том 12, 2002 Том 11, 2001 Том 10, 2000 Том 9, 1999 Том 8, 1998 Том 7, 1997 Том 6, 1996 Том 5, 1995 Том 4, 1994 Том 3, 1993 Том 2, 1992 Том 1, 1991

Atomization and Sprays

DOI: 10.1615/AtomizSpr.v18.i6.20
pages 495-510

MASS BALANCE OF NEBULIZED DRUG DELIVERY: RESIDUAL DRUG LEVELS AND THE EFFECTS OF AN ALTERNATIVE AIR HUMIDIFICATION METHOD

Benjamen A. Filas
Department of Engineering, University of Denver, 2390 South York Street, Denver, CO 80208, USA
Corinne S. Lengsfeld
Department of Mechanical and Materials Engineering, University of Denver, Denver, Colorado 80208, USA

Краткое описание

Pulmonary drug delivery through the use of in-line nebulizers is a widespread method for delivering therapeutics to mechanically ventilated patients. However, previous studies have shown that often less than 30% of salbutamol sulfate, the generic therapeutic administered to asthmatics, ever reaches the lungs. The purpose of this study was to investigate methods through which nebulized drug delivery could be improved. The first part of these experiments involved testing three brands of nebulizers to determine if substantial differences existed between models. It was found that all three of the nebulizers performed comparably. In these nebulizers, most of the drug was recovered in the nebulizer housings, indicating that most of the therapeutic never escaped the device. When humidity was applied to the driving airflow prior to the air reaching the nebulizer in an effort to reduce evaporation effects, it was found that residual salbutamol sulfate levels in the nebulizer decreased by nearly half.


Articles with similar content:

Delivery of Biotherapeutics by Inhalation Aerosol
Critical Reviews™ in Therapeutic Drug Carrier Systems, Vol.12, 1995, issue 2-3
Ralph W. Niven
PARAMETRIC STUDY OF DISC BRAKE ROTOR WITH DIAMOND AND TEAR-DROP PILLARS
ICHMT DIGITAL LIBRARY ONLINE, Vol.4, 2001, issue
Brian E. Milton, Phillip Joseph, Lisa Wallis
HIGHLY NONSTEADY TWO-PHASE-FLOW: FEASIBILITY OF A MECHANICAL PUMP SPRAY FOR DRUG DELIVERY TO THE RESPIRATORY TRACT
ICLASS 94
Proceedings of the Sixth International Conference on Liquid Atomization and Spray Systems, Vol.0, 1994, issue
R. Jager-Waldau, H. Mehring
TARGETED MEDICAL SPRAYS STIMULATING THERAPEUTIC EFFECTS
Atomization and Sprays, Vol.21, 2011, issue 4
Corinne S. Lengsfeld, Guillermo Aguilar
Nonequilibrium Atmospheric Pressure Dielectric Barrier Discharge in Ophthalmology
Plasma Medicine, Vol.3, 2013, issue 3
David Peretz, Gregory Fridman, David Pao, Mehul Gurjar, Danil Dobrynin, Kimberly Wasko, Elizabeth Curran, Robert Duffy, Alexander A. Fridman, Breanna Seiber, Sin Park, Ajay Raghavan, Ryan Smalley