Доступ предоставлен для: Guest
Портал Begell Электронная Бибилиотека e-Книги Журналы Справочники и Сборники статей Коллекции
Atomization and Sprays
Импакт фактор: 1.262 5-летний Импакт фактор: 1.518 SJR: 0.814 SNIP: 1.18 CiteScore™: 1.6

ISSN Печать: 1044-5110
ISSN Онлайн: 1936-2684

Выпуски:
Том 29, 2019 Том 28, 2018 Том 27, 2017 Том 26, 2016 Том 25, 2015 Том 24, 2014 Том 23, 2013 Том 22, 2012 Том 21, 2011 Том 20, 2010 Том 19, 2009 Том 18, 2008 Том 17, 2007 Том 16, 2006 Том 15, 2005 Том 14, 2004 Том 13, 2003 Том 12, 2002 Том 11, 2001 Том 10, 2000 Том 9, 1999 Том 8, 1998 Том 7, 1997 Том 6, 1996 Том 5, 1995 Том 4, 1994 Том 3, 1993 Том 2, 1992 Том 1, 1991

Atomization and Sprays

DOI: 10.1615/AtomizSpr.v18.i6.50
pages 553-569

EFFECT OF ENGINE NACELLE CLUTTER DENSITY ON DOWNSTREAM WATER SPRAY DISTRIBUTIONS

John M. Davis
Engineering and Scientific Innovations Inc. Batesville, IN 47006
Peter J. Disimile
Department of Aerospace Engineering, University of Cincinnati, Cincinnati, OH, USA 45221-0070

Краткое описание

This investigation presents the results of spray interactions with clutter elements in a surrounding turbulent airflow, with an emphasis on aiding the development of spray transport models to be used within a computational fire code. Many Halon replacement agents have high boiling points and discharge in a liquid state, thus resulting in the transport of liquid droplets through cluttered engine nacelles. By increasing the understanding of liquid state suppressant transport through cluttered environments, the overall effectiveness of fire suppressant systems could be increased. The current paper examines agent droplet diameter and velocity at locations upstream and downstream of a clutter package consisting of staggered cylindrical arrays of various streamwise spacing. The agent (water) was discharged upstream of the clutter from a two-phase nozzle into the main airflow. Three-dimensional droplet velocity and diameter measurements were taken upstream and downstream of the clutter, for three separate clutter densities under a constant main airflow speed of approximately 5.0 m/s and a nominal turbulence level of 10%. The downstream data are compared to the upstream distributions to provide insight into the effect of clutter density on agent distribution.


Articles with similar content:

PERFORMANCE INVESTIGATION OF AIR WASHER FOR DIFFERENT PSYCHOMETRIC CONDITIONS
Computational Thermal Sciences: An International Journal, Vol.7, 2015, issue 3
Prasanta Kumar Das, Sidharth S. Chakrabarti
EXPERIMENTAL INVESTIGATION OF DROPLET COALESCENCE IN A FULL-CONE SPRAY FROM A TWO-FLUID NOZZLE USING LASER DIFFRACTION MEASUREMENTS
Atomization and Sprays, Vol.14, 2004, issue 4
M. Valencia-Bejarano, T. A. G. Langrish
CHARACTERIZATION OF EVAPORATING DIESEL SPRAYS USING EXCIPLEX LASER-INDUCED FLUORESCENCE MEASUREMENTS
Atomization and Sprays, Vol.13, 2003, issue 5&6
J. B. Ghandhi, T. Kim
EXPERIMENTAL AND COMPUTATIONAL STUDY OF THE INFLUENCE OF PARTIAL NEEDLE LIFT ON NOZZLE FLOWIN DIESEL FUEL INJECTORS
Atomization and Sprays, Vol.22, 2012, issue 8
Jaime Gimeno, Raul Payri, Alejandro H. Plazas, O. Venegas
Characteristics of the Internal Flow in a Diesel Injection Nozzle
International Journal of Fluid Mechanics Research, Vol.24, 1997, issue 1-3
Keiya Nishida, Hiroyuki Hiroyasu, J. H. Kim