International Journal of Energy for a Clean Environment

Ранее издавался как Clean Air: International Journal on Energy for a Clean Environment

DOI: 10.1615/InterJEnerCleanEnv.2012005876
pages 175-185

THEORETICAL POSSIBILITY OF THE MAISOTSENKO CYCLE APPLICATION TO DECREASE COLD WATER TEMPERATURE IN COOLING TOWERS

Boris Sverdlin
EKOTEP Ltd., Gzhatskaya str., h. 21, lit. A, 195220 Saint Petersburg, Russia
Alexey Tikhonov
EKOTEP Ltd., Gzhatskaya str., h. 21, lit. A, 195220 Saint Petersburg, Russia
Ritta Gelfand
EKOTEP Ltd., Gzhatskaya str., h. 21, lit. A, 195220 Saint Petersburg, Russia

Краткое описание

In any explanation of cooling tower operation, it is shown that the ambient wet bulb temperature is a physical limit for water cooling. The main advantage of the Maisotsenko cycle (M-cycle) is the possibility to have the cold water temperature lower than the ambient wet bulb temperature, without violation of any physical principle. The idea is based on the fact that the ambient wet bulb temperature depends not only on the absolute humidity value, but also on a current air temperature. On the contrary, the dew point temperature depends only on the absolute humidity value. If we can provide lower temperature of the air (with the same absolute humidity) at the air inlet of the cooling tower, then the wet bulb temperature for such air will be lower. Therefore, if we can cool the air entering the cooling tower, without the change of its absolute humidity, it will be possible to cool the water more and, for some conditions, its temperature could be lower than the wet bulb temperature of the surrounding air at some distance from the cooling tower. However, the main problem is how to cool the air entering the cooling tower, very simply and without significant energy consumption. A theoretical possibility to solve this problem by application of the M-cycle is under analysis in this paper.

Ключевые слова: cooling tower, wet bulb, dew point, Maisotsenko cycle

Articles with similar content:

RESOLVING THE ENERGY–WATER NEXUS IN LARGE THERMOELECTRIC POWER PLANTS: A CASE FOR APPLICATION OF ENHANCED HEAT TRANSFER AND HIGH-PERFORMANCE THERMAL ENERGY STORAGE
Journal of Enhanced Heat Transfer, Vol.23, 2016, issue 4
Raj M. Manglik, Milind A. Jog
DEVELOPMENT AND EXPERIMENTAL TESTING OF AN ENTHALPY RECOVERY WHEEL BASED ON A NEW COMPOSITE DESICCANT
Proceedings of Symposium on Energy Engineering in the 21st Century (SEE2000) Volume I-IV, Vol.0, 2000, issue
Mouloud Amazouz , Sophie Hosatte, Roland Cote
Application of Entransy in Match Property of Liquid Desiccant Dehumidification
International Heat Transfer Conference 15, Vol.31, 2014, issue
Lun Zhang, Xiaohua Liu, Yi Jiang
SIMULATION OF NATURAL GAS COMBINED CYCLE POWER PLANT AT ELEVATED TEMPERATURES
Second Thermal and Fluids Engineering Conference, Vol.14, 2017, issue
Todd M. Bandhauer, Achyut Paudel
EFFECT OF TEMPERATURE ON NANOFIBER'S MORPHOLOGY IN ELECTROSPINNING
Heat Transfer Research, Vol.44, 2013, issue 5
Fujuan Liu, Li Zhang


У Вас нет доступа к этой статье. Пожалуйста, купите статью или авторизуйтесь на сайте и проверьте подписку