Том 46, 2019 Том 45, 2018 Том 44, 2017 Том 43, 2016 Том 42, 2015 Том 41, 2014 Том 40, 2013 Том 39, 2012 Том 38, 2011 Том 37, 2010 Том 36, 2009 Том 35, 2008 Том 34, 2007 Том 33, 2006 Том 32, 2005 Том 31, 2004 Том 30, 2003 Том 29, 2002 Том 28, 2001 Том 27, 2000 Том 26, 1999 Том 25, 1998 Том 24, 1997 Том 23, 1996 Том 22, 1995

International Journal of Fluid Mechanics Research

DOI: 10.1615/InterJFluidMechRes.v43.i3.20
pages 206-217

Secondary Flow Behaviour in Various Rounded-Edge Bifurcation T-Junctions and Its Relation to Head Loss

YB. Lukiyanto
Sanata Dharma University
I. N. G. Wardana
Mechanical Engineering Department, Brawijaya University Jln. MT. Haryono 167, Malang 65145, Indonesia
Widya Wijayanti
Mechanical Engineering Department, Brawijaya University Jln. MT. Haryono 167, Malang 65145, Indonesia
M. Agus Choiron
Mechanical Engineering Department, Brawijaya University Jln. MT. Haryono 167, Malang 65145, Indonesia

Краткое описание

Visualization of secondary flow behavior were carried out for the laminar flow (Re = 81) in a sharp-edged and rounded-edged 90° T-junction with an inlet flow perpendicular to both inline outlet flows orientation with a bifurcation ratio of 0.5. Particles were added to the fluid. The fluid was salt solution for density similarity with the particles, leading to eliminate the bouyance effect. Static pressures were measured at the inlet and one of the outlet channels by a U-manometer. The result shows that the rounded edge affected the recirculation secondary flow area and position leading to the reduction of the head loss. The image of the secondary flow demonstrates that a T-junction with the rounded edge with a rounded-edge radius ratio of 0.5 had a broader bifurcation area and a smaller secondary flow occupation area in the outlet channel, as compared to the sharp edge. The decreasing head loss ratio was 51 %. At rounded-edge radius ratio of 0 up to 1.5 part of secondary flow was located in the bifurcation area and the outlet area, whereas at rounded-edge radius ratio of 2 and of 2.5 it was located completely within the bifurcation area. Changing rounded-edge radius ratio from 1.5 to 2 reduced the head loss ratio up to 49.72 %.


Articles with similar content:

Numerical Fluid Flow and Heat Transfer Prediction of Rotating Tapered Channel
Journal of Enhanced Heat Transfer, Vol.16, 2009, issue 4
Luai M. Al-Hadhrami, Mehaboob Basha
NUMERICAL STUDY OF THE SECONDARY FLOW FORMATION OF A FLUID PASSING THROUGH A 90° ELBOW WITH SQUARE CROSS SECTION
4th Thermal and Fluids Engineering Conference, Vol.17, 2019, issue
O. M. Ayala, O. F. Ayala, Manuel Ayala
GEOMETRIC EFFECTS ON SPRAY CONE ANGLE FOR PLAIN-ORIFICE ATOMIZERS
Atomization and Sprays, Vol.1, 1991, issue 3
Arthur H. Lefebvre, Dwight W. Senser, T. R. Ohrn
EFFECT OF CAVITATION IN CIRCULAR NOZZLE AND ELLIPTICAL NOZZLES ON THE SPRAY CHARACTERISTIC
Atomization and Sprays, Vol.20, 2010, issue 10
Choong-Won Lee, Sung Ryoul Kim, Kun Woo Ku, Jung Goo Hong
COMPUTATIONAL ANALYSIS OF FLOW PATTERNS IN ELLIPTICAL DIESEL NOZZLES AT HIGH INJECTION PRESSURES
Atomization and Sprays, Vol.28, 2018, issue 11
Bifeng Yin, Bin Xu, Shenghao Yu, Ze Ye, Huaping Xu, Hekun Jia, Weixin Deng