Доступ предоставлен для: Guest
Портал Begell Электронная Бибилиотека e-Книги Журналы Справочники и Сборники статей Коллекции
International Journal of Fluid Mechanics Research
ESCI SJR: 0.206 SNIP: 0.446 CiteScore™: 0.5

ISSN Печать: 2152-5102
ISSN Онлайн: 2152-5110

Выпуски:
Том 46, 2019 Том 45, 2018 Том 44, 2017 Том 43, 2016 Том 42, 2015 Том 41, 2014 Том 40, 2013 Том 39, 2012 Том 38, 2011 Том 37, 2010 Том 36, 2009 Том 35, 2008 Том 34, 2007 Том 33, 2006 Том 32, 2005 Том 31, 2004 Том 30, 2003 Том 29, 2002 Том 28, 2001 Том 27, 2000 Том 26, 1999 Том 25, 1998 Том 24, 1997 Том 23, 1996 Том 22, 1995

International Journal of Fluid Mechanics Research

DOI: 10.1615/InterJFluidMechRes.v42.i2.50
pages 149-169

Computational Analysis of Transient non-Newtonian Blood Flow in Magnetic Targeting Drug Delivery in Stenosed Carotid Bifurcation Artery

Haleh Alimohamadi
PhD student
Mohsen Imani
School of Electrical and Computer Engineering, University of Tehran Tehran, Iran
Behjat Forouzandeh
School of Electrical and Computer Engineering, University of Tehran Tehran, Iran

Краткое описание

This paper presents pulsatile blood flow simulation in a carotid bifurcation under the action of external magnetic field. Previous investigations neglected the effect of transient magnetic field on non-Newtonian blood flow through a coupled free and porous media. In this study for closing to a real phenomenon, arterial walls and two fatty deposited atherosclerotic plaques are considered as different porous media, blood is assumed as a generalized non-Newtonian biomagnetic fluid (with Power law and Carreau models) and time dependent inlet velocity varies by the frequency of human heart beating cycle. Because of magnetic field existence, two big vortexes are created at the plaques' edges and the temperature, shear stress, vertical velocity and pressure distribution along the stenosis region have been affected noticeably. The results show by applying MnF = 107 and MnM = 102 magnetic field intensity the values of temperature, absolute maximum pressure and shear stress go up 7.35 %, 5.55 times and 5.33 times (62.16 %,4.08 times and 6 times) respect with normal condition on the upper (lower) plaques respectively. Examining the role of porosity factor indicates that by progressing stenosis disease and hardening atherosclerotic plaques, magnetotherapy treatment lose its efficiency due to sever reduction in available maximum blood temperature, fluid flux and average Nusselt number.


Articles with similar content:

Effect of Restriction and Reynolds Number on the Pressure of Blood of a Stenotic Artery
International Journal of Fluid Mechanics Research, Vol.34, 2007, issue 2
Somnath Chakrabarti, Dipak Kumar Mandal
NON-NEWTONIAN PULSATILE FLOW IN AN ABDOMINAL AORTA − RENAL ARTERY JUNCTION
Proceedings of the 24th National and 2nd International ISHMT-ASTFE Heat and Mass Transfer Conference (IHMTC-2017), Vol.0, 2017, issue
Mohan Anand, Mohammed Ameenuddin
NUMERICAL SIMULATION OF BLOOD FLOW IN HEALTHY ARTERIES BY USE OF THE SISKO MODEL
Computational Thermal Sciences: An International Journal, Vol.8, 2016, issue 4
Shahin Shareghi , Davood Toghraie
INFLUENCE OF HALL CURRENT ON OSCILLATORY COUETTE FLOW IN THE PRESENCE OF AN INCLINED MAGNETIC FIELD THROUGH POROUS MEDIUM
Journal of Porous Media, Vol.17, 2014, issue 1
Constantin Fetecau, Saira Saeed, M. Azram, Masood Khan
On Blood Flow in an Artery with an Unsteady Overlapping Stenosis: Mathematical and Computer Modeling
International Journal of Fluid Mechanics Research, Vol.40, 2013, issue 1
Daniel N. Riahi, Ranadhir Roy