每年出版 8 期
ISSN 打印: 2150-3621
ISSN 在线: 2150-363X
Indexed in
EXPERIMENTAL STUDY OF LPG AND R134a REFRIGERANTS IN VAPOR COMPRESSION REFRIGERATION
摘要
Natural refrigerants, such as hydrocarbons, have been renewed in recent years as a result of the environmental problems associated with chlorofluorocarbon (CFC) and hydro-chlorofluorocarbon (HCFC) refrigerants. Due to the depletion of the ozone layer and global warming effects, synthetic refrigerants are being gradually phased out in accordance with the international protocols that aim to protect the environment. A refrigerator designed to work with R134a was used for this experiment, liquefied petroleum gas (LPG) which consists of 60% propane (R290) and 40% butane (R600) was compared with R134a refrigerant in a vapor compression refrigerator with a total volume of 62 L. The experiments were carried out using different charges of 40, 60, 80, and 100 g for R134a and LPG refrigerants, the charges were measured with a digital charging scale. The K-type thermocouples were used to measure the temperatures at the inlet and outlet of the four major components (evaporator, compressor, condenser, and expansion device) of the refrigeration system. The system was instrumented with two pressure gauges at the inlet and outlet of the compressor for measuring the suction and discharge pressures. The results obtained were used to determine the thermodynamic properties of the refrigerants using Refprop, version 9. The results obtained showed that the design temperature and pull-down time set by the International Standard Organisation (ISO) for a refrigerator were achieved with LPG earlier than with R134a. The coefficient of performance (COP) of the system increases by 9.5% and the power consumption is reduced by 12%, when compared with R134a. Therefore, LPG can successfully substitute R134a in domestic refrigerators.
-
Gill Jatinder, Singh Jagdev, An applicability of ANFIS approach for depicting energetic performance of VCRS using mixture of R134a and LPG as refrigerant, International Journal of Refrigeration, 85, 2018. Crossref
-
Gill Jatinder, Singh Jagdev, Performance analysis of vapor compression refrigeration system using an adaptive neuro-fuzzy inference system, International Journal of Refrigeration, 82, 2017. Crossref
-
Gill Jatinder, Singh Jagdev, Energetic and exergetic performance analysis of the vapor compression refrigeration system using adaptive neuro-fuzzy inference system approach, Experimental Thermal and Fluid Science, 88, 2017. Crossref
-
Gill Jatinder, Singh Jagdev, Use of artificial neural network approach for depicting mass flow rate of R134a /LPG refrigerant through straight and helical coiled adiabatic capillary tubes of vapor compression refrigeration system, International Journal of Refrigeration, 86, 2018. Crossref
-
Gill Jatinder, Singh Jagdev, Energy analysis of vapor compression refrigeration system using mixture of R134a and LPG as refrigerant, International Journal of Refrigeration, 84, 2017. Crossref
-
Gill Jatinder, Singh Jagdev, Component-wise exergy and energy analysis of vapor compression refrigeration system using mixture of R134a and LPG as refrigerant, Heat and Mass Transfer, 54, 5, 2018. Crossref
-
Ayomide Orhewere B., Ajayi Oluseyi O., Banjo Solomon O., Ajayi Adesola A., Data on the no-load performance analysis of a tomato postharvest storage system, Data in Brief, 13, 2017. Crossref
-
Gill Jatinder, Singh Jagdev, Experimental Analysis of R134a/LPG as Replacement of R134a in a Vapor-Compression Refrigeration System, International Journal of Air-Conditioning and Refrigeration, 25, 02, 2017. Crossref
-
Gill Jatinder, Singh Jagdev, Ohunakin Olayinka S., Adelekan Damola S., Energetic and exergetic analysis of a domestic refrigerator system with LPG as a replacement for R134a refrigerant, using POE lubricant and mineral oil based TiO2-, SiO2- and Al2O3-lubricants, International Journal of Refrigeration, 91, 2018. Crossref
-
Gill Jatinder, Singh Jagdev, Depicting mass flow rate of R134a /LPG refrigerant through straight and helical coiled adiabatic capillary tubes of vapor compression refrigeration system using artificial neural network approach, Heat and Mass Transfer, 54, 7, 2018. Crossref
-
Gill Jatinder, Singh Jagdev, Ohunakin Olayinka S., Adelekan Damola S., Energy analysis of a domestic refrigerator system with ANN using LPG/TiO2–lubricant as replacement for R134a, Journal of Thermal Analysis and Calorimetry, 135, 1, 2019. Crossref
-
Gill Jatinder, Singh Jagdev, Ohunakin Olayinka S., Adelekan Damola S., Artificial neural network approach for irreversibility performance analysis of domestic refrigerator by utilizing LPG with TiO 2 –lubricant as replacement of R134a, International Journal of Refrigeration, 89, 2018. Crossref
-
Babarinde T. O., Akinlabi S. A., Madyira D. M., Enhancing the Performance of Vapour Compression Refrigeration System using Nano Refrigerants: A review, IOP Conference Series: Materials Science and Engineering, 413, 2018. Crossref
-
Ohunakin Olayinka S., Adelekan Damola S., Gill Jatinder, Atayero Aderemi A., Atiba Opemipo E., Okokpujie Imhade P., Abam Fidelis I., Performance of a hydrocarbon driven domestic refrigerator based on varying concentration of SiO2 nano-lubricant, International Journal of Refrigeration, 94, 2018. Crossref
-
Ahmad Rakibul Hossain, Bhuiyan Arafat A., Xu Fei, Sujon Abu Shaid, Karim Md. Rezwanul, Moin Emran Hossain, Sadrul Islam A. K. M., Comparative analysis of refrigerant performance between LPG and R134a under subtropical climate, Journal of Thermal Analysis and Calorimetry, 139, 4, 2020. Crossref
-
Madyira D. M., Marangwanda G.T., Ekundayo F.M., Babarinde T. O., Akinlabi S.A., Investigation of Household Refrigerator System with Varied Capillary Tube Length, Journal of Physics: Conference Series, 1378, 4, 2019. Crossref
-
Yunus Mohammed, Oreijah Mowffaq M, Performance characteristics of a heat pump using renewable transcritical CO2 refrigerant for heating water, International Journal of Low-Carbon Technologies, 16, 3, 2021. Crossref
-