Erscheint 6 Ausgaben pro Jahr
ISSN Druckformat: 0278-940X
ISSN Online: 1943-619X
Indexed in
A Review of Nondestructive Test Methods and Their Application to Measure the Stability and Osseointegration of Bone Anchored Endosseous Implants
ABSTRAKT
Threaded and cylindrical metallic endosseous implants are being used increasingly in cranio-facial, dental, and orthopedic surgery. There is a significant need for the development of quantitative noninvasive test methods to measure implant stability and success. Such success can be quantified by measurements of the stiffness and damping of an implant in the surrounding bone, and also the height of the marginal bone around an implant. In the case of a failing implant, the bone around it is replaced by fibrous tissue, and in the case of an overloaded implant the bone height around the implant falls. Nondestructive test methods have been applied to the testing of implant and tooth mobility, and commonly these have used transient or steady-state test methods. Transient methods entail tapping an implant, measuring its response and then performing a Fast Fourier Transform to resolve the fundamental frequencies. Steady-state methods measure the frequency response of a system using a swept frequency wave form. A number of dedicated electronic instruments have been designed to perform these tasks, and this article discusses their applications, accuracy, and value as clinical diagnostic instruments.
-
Szivek J.A., Margolis D.S., Garrison B.K., Nelson E., Vaidyanathan R.K., DeYoung D.W., TGF-?1-enhanced TCP-coated sensate scaffolds can detect bone bonding, Journal of Biomedical Materials Research Part B: Applied Biomaterials, 73B, 1, 2005. Crossref
-
Heschl Alexander, Payer Michael, Platzer Susanne, Wegscheider Walther, Pertl Christof, Lorenzoni Martin, Immediate rehabilitation of the edentulous mandible with screw type implants: results after up to 10 years of clinical function, Clinical Oral Implants Research, 23, 10, 2012. Crossref
-
Cochran David L., Buser Daniel, Ten Bruggenkate Christian M., Weingart Dieter, Taylor Thomas M., Bernard Jean-Pierre, Peters Françoise, Simpson James P., The use of reduced healing times on ITI® implants with a sandblasted and acid-etched (SLA) surface:, Clinical Oral Implants Research, 13, 2, 2002. Crossref
-
Huang Haw-Ming, Lee Sheng-Yang, Yeh Ching-Ying, Lin Che-Tong, Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach, Clinical Oral Implants Research, 13, 1, 2002. Crossref
-
Tabrizi Aydin, Rizzo Piervincenzo, Ochs Mark W, Electromechanical impedance method to assess dental implant stability, Smart Materials and Structures, 21, 11, 2012. Crossref
-
Fundamentals of Materials Science, in Craig's Restorative Dental Materials, 2012. Crossref
-
Hammerle Christoph H. F., Glauser Roland, Clinical evaluation of dental implant treatment, Periodontology 2000, 34, 1, 2004. Crossref
-
Monov Gabriel, Fuerst Gabor, Tepper Gabor, Watzak Georg, Zechner Werner, Watzek Georg, The effect of platelet-rich plasma upon implant stability measured by resonance frequency analysis in the lower anterior mandibles, Clinical Oral Implants Research, 16, 4, 2005. Crossref
-
Berhanu Bruk, Rizzo Piervincenzo, Ochs Mark, Highly Nonlinear Solitary Waves for the Assessment of Dental Implant Mobility, Journal of Applied Mechanics, 80, 1, 2013. Crossref
-
Stacchi Claudio, Vercellotti Tomaso, Torelli Lucio, Furlan Fabio, Di Lenarda Roberto, Changes in Implant Stability Using Different Site Preparation Techniques: Twist Drills versus Piezosurgery. A Single-Blinded, Randomized, Controlled Clinical Trial, Clinical Implant Dentistry and Related Research, 15, 2, 2013. Crossref
-
Huwiler M. A., Pjetursson B. E., Bosshardt D. D., Salvi G. E., Lang N. P., Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installation, Clinical Oral Implants Research, 18, 3, 2007. Crossref
-
Ertugrul H Zeynep, Pipko Donald J., Measuring Mobility of 2 Dental Implant Fixtures of Different Configurations: An In Vitro Study, Implant Dentistry, 15, 3, 2006. Crossref
-
Alsaadi Ghada, Quirynen Marc, Michiels Katleen, Jacobs Reinhilde, van Steenberghe Daniel, A biomechanical assessment of the relation between the oral implant stability at insertion and subjective bone quality assessment, Journal of Clinical Periodontology, 34, 4, 2007. Crossref
-
Aparicio Carlos, Lang Niklaus P., Rangert Bo, Validity and clinical significance of biomechanical testing of implant/bone interface, Clinical Oral Implants Research, 17, S2, 2006. Crossref
-
Pan Min-Chun, Zhuang Han-Bo, Chen Chin-Sung, Wu Jer-Whey, Lee Shyh-Yuan, A noncontact resonance frequency detection technique for the assessment of the interfacial bone defect around a dental implant, Medical Engineering & Physics, 35, 12, 2013. Crossref
-
Parithimarkalaignan S., Padmanabhan T. V., Osseointegration: An Update, The Journal of Indian Prosthodontic Society, 13, 1, 2013. Crossref
-
Chowdhary Ramesh, Halldin Anders, Jimbo Ryo, Wennerberg Ann, Influence of Micro Threads Alteration on Osseointegration and Primary Stability of Implants: An FEA and In Vivo Analysis in Rabbits, Clinical Implant Dentistry and Related Research, 17, 3, 2015. Crossref
-
von Wilmowsky Cornelius, Moest Tobias, Nkenke Emeka, Stelzle Florian, Schlegel Karl Andreas, Implants in bone: Part II. Research on implant osseointegration, Oral and Maxillofacial Surgery, 18, 4, 2014. Crossref
-
Manresa Carolina, Bosch Manel, Echeverría José J., The comparison between implant stability quotient and bone-implant contact revisited: an experiment in Beagle dog, Clinical Oral Implants Research, 25, 11, 2014. Crossref
-
Cooper Lyndon F., A role for surface topography in creating and maintaining bone at titanium endosseous implants, The Journal of Prosthetic Dentistry, 84, 5, 2000. Crossref
-
O'Sullivan Dominic, Sennerby Lars, Jagger Daryll, Meredith Neil, A Comparison of Two Methods of Enhancing Implant Primary Stability, Clinical Implant Dentistry and Related Research, 6, 1, 2004. Crossref
-
Dinh Andrew, Sheets Cherilyn G., Earthman James C., Analysis of percussion response of dental implants: An in vitro study, Materials Science and Engineering: C, 33, 5, 2013. Crossref
-
Lee Su-Young, Piao Chunmei, Heo Seong-Joo, Koak Jai-Young, Lee Joo-Hee, Kim Tae-Hyung, Kim Myung-Joo, Kwon Ho-Beom, Kim Seong-Kyun, A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables, The Journal of Advanced Prosthodontics, 2, 4, 2010. Crossref
-
Verdonck Henk W. D., Meijer Gert J., Laurin Thorsten, Nieman Fred H., Stoll Christian, Riediger Dieter, Stoelinga Paul J. W., Baat Cees de, Implant stability during osseointegration in irradiated and non-irradiated minipig alveolar bone: an experimental study, Clinical Oral Implants Research, 19, 2, 2008. Crossref
-
Zhou Wei, Han Chun, Yunming Li, Li Dehua, Song Yingliang, Zhao Yimin, Is the osseointegration of immediately and delayed loaded implants the same?���comparison of the implant stability during a 3-month healing period in a prospective study, Clinical Oral Implants Research, 20, 12, 2009. Crossref
-
Karl Matthias, Graef Friedrich, Heckmann Siegfried, Krafft Tim, Parameters of resonance frequency measurement values: a retrospective study of 385 ITI dental implants, Clinical Oral Implants Research, 19, 2, 2008. Crossref
-
BROUWERS J. E. I. G., LOBBEZOO F., VISSCHER C. M., WISMEIJER D., NAEIJE M., Reliability and validity of the instrumental assessment of implant stability in dry human mandibles, Journal of Oral Rehabilitation, 36, 4, 2009. Crossref
-
Kim Seong-Kyun, Heo Seong-Joo, Koak Jai-Young, Lee Joo-Hee, Kwon Ji-Yong, Development of predictable stability test for assessment of optimum loading time in dental implant, The Journal of Korean Academy of Prosthodontics, 46, 6, 2008. Crossref
-
Qian Shu-Jiao, Gu Ying-Xin, Mo Jia-Ji, Qiao Shi-Chong, Zhuang Long-Fei, Lai Hong-Chang, Resonance frequency analysis of implants placed with osteotome sinus floor elevation in posterior maxillae, Clinical Oral Implants Research, 27, 1, 2016. Crossref
-
Zhuang H.B., Pan M.Ch., Chen J.Z., Wu J.W., Chen C.S., A noncontact detection technique for interfacial bone defects and osseointegration assessment surrounding dental implants, Measurement, 55, 2014. Crossref
-
Sul Young-Taeg, Jönsson Jörgen, Yoon Goui-Seong, Johansson Carina, Resonance frequency measurementsin vivoand related surface properties of magnesium-incorporated, micropatterned and magnesium-incorporated TiUnite®, Osseotite®, SLA®and TiOblast®implants, Clinical Oral Implants Research, 20, 10, 2009. Crossref
-
Choi Jin Hwan, Yu Hyung Seog, Lee Kee Joon, Park Young Chel, Three-dimensional evaluation of maxillary anterior alveolar bone for optimal placement of miniscrew implants, The Korean Journal of Orthodontics, 44, 2, 2014. Crossref
-
Hsieh Sung-Chih, Lee Sheng-Yang, Ciou Chun-Yu, Huang Haw-Ming, Non-destructive natural frequency tests of cyclic fatigue-loaded nickel–titanium rotary instruments, Medical & Biological Engineering & Computing, 48, 6, 2010. Crossref
-
Berthold Christine, Holst Stefan, Schmitt Johannes, Goellner Matthias, Petschelt Anselm, An evaluation of the Periotest®method as a tool for monitoring tooth mobility in dental traumatology, Dental Traumatology, 26, 2, 2010. Crossref
-
Han Jie, Lulic Martina, Lang Niklaus P., Factors influencing resonance frequency analysis assessed by Osstell™mentor during implant tissue integration: II. Implant surface modifications and implant diameter, Clinical Oral Implants Research, 21, 6, 2010. Crossref
-
Shadid Rola Muhammed, Sadaqah Nasrin Rushdi, Othman Sahar Abdo, Does the Implant Surgical Technique Affect the Primary and/or Secondary Stability of Dental Implants? A Systematic Review, International Journal of Dentistry, 2014, 2014. Crossref
-
Rodrigo Daniel, Aracil Luis, Martin Conchita, Sanz Mariano, Diagnosis of implant stability and its impact on implant survival: a prospective case series study, Clinical Oral Implants Research, 21, 3, 2010. Crossref
-
Deli Giorgio, Petrone Vincenzo, De Risi Valeria, Tadic Drazen, Zafiropoulos Gregory-George, Longitudinal Implant Stability Measurements Based on Resonance Frequency Analysis After Placement in Healed or Regenerated Bone, Journal of Oral Implantology, 40, 4, 2014. Crossref
-
Torroella-Saura Gerard, Mareque-Bueno Javier, Cabratosa-Termes Josep, Hernández-Alfaro Federico, Ferrés-Padró Eduard, Calvo-Guirado José Luis, Effect of implant design in immediate loading. A randomized, controlled, split-mouth, prospective clinical trial, Clinical Oral Implants Research, 26, 3, 2015. Crossref
-
CHANG Wei-Jen, LEE Sheng-Yang, WU Chen-Che, LIN Che-Tong, ABIKO Yoshimitsu, YAMAMICHI Nobuyuki, HUANG Haw-Ming, A Newly Designed Resonance Frequency Analysis Device for Dental Implant Stability Detection, Dental Materials Journal, 26, 5, 2007. Crossref
-
Schliephake H., Sewing A., Aref A., Resonance frequency measurements of implant stability in the dog mandible: experimental comparison with histomorphometric data, International Journal of Oral and Maxillofacial Surgery, 35, 10, 2006. Crossref
-
Park Joorok, Cho Heon Jae, Three-dimensional evaluation of interradicular spaces and cortical bone thickness for the placement and initial stability of microimplants in adults, American Journal of Orthodontics and Dentofacial Orthopedics, 136, 3, 2009. Crossref
-
Earthman James C., Li Yong, VanSchoiack Lindsey R., Sheets Cherilyn G., Wu Jean C., Reconstructive Materials and Bone Tissue Engineering in Implant Dentistry, Dental Clinics of North America, 50, 2, 2006. Crossref
-
Winter W., Krafft T., Steinmann P., Karl M., Quality of alveolar bone — Structure-dependent material properties and design of a novel measurement technique, Journal of the Mechanical Behavior of Biomedical Materials, 4, 4, 2011. Crossref
-
Huang Haw-Ming, Chang Wei-Jen, Teng Nai-Chia, Lin Hung-Lung, Hsieh Sung-Chih, Structural Analysis of Cyclic-loaded Nickel-Titanium Rotary Instruments by Using Resonance Frequency as a Parameter, Journal of Endodontics, 37, 7, 2011. Crossref
-
Boemio Giovanni, Rizzo Piervincenzo, Nardo Luigi De, Assessment of dental implant stability by means of the electromechanical impedance method, Smart Materials and Structures, 20, 4, 2011. Crossref
-
Wilmes B., Drescher D., Impact of bone quality, implant type, and implantation site preparation on insertion torques of mini-implants used for orthodontic anchorage, International Journal of Oral and Maxillofacial Surgery, 40, 7, 2011. Crossref
-
Omer Khaled, Fox Kathryn, Palermo Deniel, Boyle Liam, Youngson Callum, An in vitro evaluation of resonant frequency analysis to measure fixed bridge stability, BDJ Open, 1, 1, 2015. Crossref
-
Berthold Christine, Auer Friedrich Johannes, Potapov Sergej, Petschelt Anselm, Development of new artificial models for splint rigidity evaluation, Dental Traumatology, 27, 5, 2011. Crossref
-
Park In-Phill, Kim Seong-Kyun, Lee Shin-Jae, Lee Joo-Hee, The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia, The Journal of Advanced Prosthodontics, 3, 2, 2011. Crossref
-
Young M. P. J., Quayle A. A., Sloan P., Carter D. H., A Survey of Clinical Members of The Association of Dental Implantology in the United Kingdom. Part III. The Use of Augmentation Techniques in Dental Implant Surgery, Implant Dentistry, 10, 4, 2001. Crossref
-
PARK K.-J., KWON J.-Y., KIM S.-K., HEO S.-J., KOAK J.-Y., LEE J.-H., LEE S.-J., KIM T.-H., KIM M.-J., The relationship between implant stability quotient values and implant insertion variables: a clinical study, Journal of Oral Rehabilitation, 39, 2, 2012. Crossref
-
Anil Sukumaran, Aldosari Abdullah Alfarraj, Impact of Bone Quality and Implant Type on the Primary Stability: An Experimental Study Using Bovine Bone, Journal of Oral Implantology, 41, 2, 2015. Crossref
-
Ghanem Walid A., Sadakah Abdelfattah A., Effect of implant length on the stability and osseointegration of immediate implant, Egyptian Journal of Oral & Maxillofacial Surgery, 7, 2, 2016. Crossref
-
Topcuoglu Tolga, Bicakci A. Altuğ, Avunduk M. Cihat, Sahin Inan Z. Deniz, Evaluation of the Effects of Different Surface Configurations on Stability of Miniscrews, The Scientific World Journal, 2013, 2013. Crossref
-
Wilmes Benedict, Drescher Dieter, Impact of Insertion Depth and Predrilling Diameter on Primary Stability of Orthodontic Mini-implants, The Angle Orthodontist, 79, 4, 2009. Crossref
-
Huang H-M, Cheng K-Y, Chen C-F, Ou K-L, Lin C-T, Lee S-Y, Design of a stability-detecting device for dental implants, Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 219, 3, 2005. Crossref
-
Pirpir Cagasan, Yilmaz Onur, Candirli Celal, Balaban Emre, Evaluation of effectiveness of concentrated growth factor on osseointegration, International Journal of Implant Dentistry, 3, 1, 2017. Crossref
-
Huang Zhengfei, Wang Zhifeng, Li Chuanhua, Yin Kaifeng, Hao Dan, Lan Jing, Application of Plasma-Sprayed Zirconia Coating in Dental Implants: Study in Implants, Journal of Oral Implantology, 44, 2, 2018. Crossref
-
BANKOĞLU GÜNGÖR Merve, KARAKOCA NEMLİ Seçil, BAĞKUR Meral, KOCACIKLI Mustafa, Termomekanik yaşlandırmanın farklı seramik abutmentlara sahip implantların stabilitesine etkisi, Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi, 2019. Crossref
-
Das Siddhartha, Dholam Kanchan, Gurav Sandeep, Bendale Kiran, Ingle Arvind, Mohanty Bhabani, Chaudhari Pradip, Bellare Jayesh R., Accentuated osseointegration in osteogenic nanofibrous coated titanium implants, Scientific Reports, 9, 1, 2019. Crossref
-
Mumcu Emre, Beklen Arzu, The effect of smoking on the marginal bone loss around implant-supported prostheses, Tobacco Induced Diseases, 17, May, 2019. Crossref
-
BANKOĞLU GÜNGÖR Merve, KARAKOCA NEMLİ Seçil, BAĞKUR Meral, KOCACIKLI Mustafa, TERMOMEKANİK YAŞLANDIRMANIN FARKLI SERAMİK ABUTMENTLARA SAHİP İMPLANTLARIN STABİLİTESİNE ETKİSİ, Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi, 2019. Crossref
-
Covani Ugo, Giammarinaro Enrica, Marconcini Simone, Aizcorbe-Vicente Javier, Peñarrocha-Diago Miguel, Diagnosis and Planning in Immediate Loading: Implant Selection, in Atlas of Immediate Dental Implant Loading, 2019. Crossref
-
Covani Ugo, Giammarinaro Enrica, Toti Paolo, Soto-Peñaloza David, Menchini Fabris Giovanni B., Marconcini Simone, Diagnosis and Planning in Immediate Loading: Surgical Diagnosis, in Atlas of Immediate Dental Implant Loading, 2019. Crossref
-
Orenstein Ira H., MacDonald Daniel E., Tao Anita C., Morris Harold F., Electronic Percussive Testing of the Stability of an Immediately Provisionalized Implant Placed Into a Fresh Extraction Socket: A Pilot Evaluation, Journal of Oral Implantology, 33, 2, 2007. Crossref
-
İZGİ Eda, ŞİMŞEK Mehmet, Dental implantlarda stabilite ölçüm yöntemleri: Derleme, Turkish Journal of Clinics and Laboratory, 2020. Crossref
-
Fundamentals of Materials Science, in Craig's Restorative Dental Materials, 2019. Crossref
-
Pan Min-Chun, Wang Shih-Yao, Chen Chin-Sung, Handheld device for assessing dental implant osseointegration through the vibro-acoustic technique, Measurement, 169, 2021. Crossref
-
Mohamed Mostafa, Pisavadia Harshil, Westover Lindsey, A finite element model for evaluating the effectiveness of the Advanced System for Implant Stability Testing (ASIST), Journal of Biomechanics, 124, 2021. Crossref
-
Gus’kov A.V., Oleinikov A.A., Domashkevich N.S., Osman A., Possibilities and prospects for experimental and clinical instrumentation techniques for determining the primary stability of dental implants in comparative analysis, Stomatologiya, 101, 1, 2022. Crossref
-
Swider P., Guérin G., Baas Joergen, Søballe Kjeld, Bechtold Joan E., Characterization of bone-implant fixation using modal analysis: Application to a press-fit implant model, Journal of Biomechanics, 42, 11, 2009. Crossref
-
Lee Jungwon, Seol Yang-Jo, Lee Yong-Moo, Koo Ki-Tae, A Narrative Review of Contemporary Evaluation Methods for Root Analog Implants, Journal of implantology and applied sciences, 26, 1, 2022. Crossref
-
Miyamoto Ikuya, Tsuboi Yoichi, Wada Eishin, Suwa Hirohiko, Iizuka Tadahiko, Influence of cortical bone thickness and implant length on implant stability at the time of surgery—clinical, prospective, biomechanical, and imaging study, Bone, 37, 6, 2005. Crossref
-
Wijaya Sastra Kusuma, Oka Hisao, Saratani Keiji, Sumikawa Takuya, Kawazoe Takayoshi, Development of implant movement checker for determining dental implant stability, Medical Engineering & Physics, 26, 6, 2004. Crossref
-
Kochetkova Tatiana, Groetsch Alexander, Indermaur Michael, Peruzzi Cinzia, Remund Stefan, Neuenschwander Beat, Bellon Benjamin, Michler Johann, Zysset Philippe, Schwiedrzik Jakob, Assessing minipig compact jawbone quality at the microscale, Journal of the Mechanical Behavior of Biomedical Materials, 134, 2022. Crossref