Proposed Frequencies of a Vibrator Used for Implant Retrieval at the Time of Hip Joint Revision Surgery

Volumen 19, Edición 2, 2009, pp. 157-165
DOI: 10.1615/JLongTermEffMedImplants.v19.i2.70
Get accessGet access

SINOPSIS

The number and the rate of success of hip implantation surgeries have increased significantly during last thirty years, not only in the USA, but also throughout the world. It has been reported that the failure rates of implanted hip joints are less than 8% after 10 years, and less than 20% after twenty years. Failures occur directly or indirectly due to wear, stress shielding and infection. Revision surgery is needed for those failed implant replacements. In the future, as the elderly population increases, the frequency of this type of revision surgery will also increase. At the time of revision surgery, removal of the existing cemented femoral implant can be a problem for the surgeon. Use of a vibrator for loosening of the existing cement layer between the bone and the implant may be a helpful solution. In this study, we investigated the optimum resonance frequencies of such a vibrator that might be used to loosen the cement layer easily and efficiently. Natural frequencies of different-sized implants and of different materials were determined. For harmonic analysis, CT scan data of a femur was processed in the image processing software MIMICS. Then the outline of the total hip was modeled and was analyzed by the finite element software ANSYS. The required portion of the femoral part was edited, implant and cement layer were introduced in that model, and elements were generated in that FEA software. Then elements of the femoral part, except the cement layer and the implant, were sent to MIMICS software again for assignment of different Young’s modulus of each element, which are proportionate to their densities. Then the elements were brought back to the FEA software. The harmonic analysis was performed for the total model in the FEA software ANSYS. For that particular boundary condition, the first three natural frequencies of the three types of implant sizes and materials varied by a maximum of 7−8%. Results of the numerical harmonic analysis showed that at the bone-cement interface, the resonance frequencies were at the ranges of 4 to 6 Hz, 26 to 29 Hz, and 43 to 49 Hz. The vibration response was similar for three cement-bone interface locations examined. This suggests that a vibrator that will produce a resonance frequency response may cause cracks in the bone-cement mantle and thus may facilitate the removal of the failed femoral component. Retrieval of hip implant may be easier using a vibrator in that band of frequencies with a moderate amplitude. The magnitude of those frequencies may not differ significantly from implant to implant as the natural frequencies of different types of implant, for that particular boundary conditions, are within a close range.

Próximos Artículos

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Portal Digitalde Biblioteca Digital eLibros Revistas Referencias y Libros de Ponencias Colecciones Precios y Políticas de Suscripcione Begell House Contáctenos Language English 中文 Русский Português German French Spain