Suscripción a Biblioteca: Guest
Journal of Long-Term Effects of Medical Implants

Publicado 4 números por año

ISSN Imprimir: 1050-6934

ISSN En Línea: 1940-4379

SJR: 0.184 SNIP: 0.485 CiteScore™:: 1.1 H-Index: 39

Indexed in

Can Marine Mammals Be a Reliable Source for the Manufacture of Prosthetic Heart Valves for Percutaneous Surgery?

Volumen 22, Edición 2, 2012, pp. 113-126
DOI: 10.1615/JLongTermEffMedImplants.v22.i2.20
Get accessGet access

SINOPSIS

Marine mammals experience unique physiological conditions when diving. Myocardial function is sustained despite a 90% reduction of the blood flow in the coronaries. Therefore, their heart valves and pericardium could serve as a unique source of tissue for the manufacture of prosthetic heart valves. The pericardium of a stillborn pup sea lion was investigated to determine its morphology using gross observation, scanning electron microscopy (SEM), light microscopy, and transmission electron microscopy (TEM). Depending upon the site of sampling, the structure of the pericardium varied significantly. The atrial sample was well structured with wavy bundles of collagen fibers. The thickness in the atrial sample was regular with a smooth serous surface. The fibrous side of the pericardium of the auricular sample was irregular and incorporated microcapillaries. Both the sternoperitoneal ligament and the phrenoperitoneal ligament section were irregular and incorporated various amounts of adipocytes. Because of the increased amount of adipocytes, the fibrils of the collagen fibers were also observed to be occasionally agglutinated. Practically, the harvesting of pericardium would have to be restricted to the atrial surface. The presence of adipocytes in the pericardium wall makes the selection of this tissue a poor choice compared to alternative existing tissue sources.

CITADO POR
  1. Mao J., Wang Y., Philippe E., Cianciulli T., Vesely I., How D., Bourget J.-M., Germain L., Zhang Z., Guidoin R., Microstructural alterations owing to handling of bovine pericardium to manufacture bioprosthetic heart valves: A potential risk for cusp dehiscence, Morphologie, 101, 333, 2017. Crossref

  2. Mao Jifu, Rassoli Aisa, Tong Yiwei, Rouse Elizabeth Nicole, Le‐Bel Gaёtan, How Daniel, Germain Lucie, Fatouraee Nasser, Zhang Ze, Reed Robert R., Guidoin Robert, Donkey pericardium compares favorably with commercial xenopericardia used in the manufacture of transcatheter heart valves, Artificial Organs, 43, 10, 2019. Crossref

  3. Meng S., Mao J., Rouse E.N., Le-Bel G., Bourget J.M., Reed R.R., Philippe E., How D., Zhang Z., Germain L., Guidoin R., The Red Kangaroo pericardium as a material source for the manufacture of percutaneous heart valves, Morphologie, 103, 341, 2019. Crossref

  4. Rassoli Aisa, Li Yiming, Bao Xianhao, Kawecki Fabien, Zhao Xinzhe, Chappard Daniel, Le-Bel Gaëtan, Feng Jiaxuan, Weber Benedikt, Fatouraee Nasser, Zhang Ze, Jing Zaiping, Germain Lucie, Wang Lu, Guidoin Robert, Donkey pericardium as a select sourcing to manufacture percutaneous heart valves: Decellularization has not yet demonstrated any clear cut advantage to glutaraldehyde treatment, Medicine in Novel Technology and Devices, 4, 2019. Crossref

826 Vistas de artículos 18 Descargas de artículos Métrica
826 PUNTOS DE VISTA 18 DESCARGAS 4 Crossref CITAS Google
Scholar
CITAS

Artículos con contenido similar:

Complications Following Intraosseous Injections of Calcium Phosphate Bone Cement in Subchondroplasty Journal of Long-Term Effects of Medical Implants, Vol.34, 2024, issue 4
Helen C. Leligou, Panayiotis J. Papagelopoulos, Olga D. Savvidou, Christos B. Zachariadis, Stauros K. Kourkoulis, Evaggelos Magnisalis
Cast-Based Guided Implant Placement and Prosthetic Rehabilitation of a Single Edentulous Space: Case Report and Systematic Analysis of Surgical Guides Used in Implant Dentistry Journal of Long-Term Effects of Medical Implants, Vol.31, 2021, issue 4
Neeti Swarup, Manjit Kumar, Megha Chopra, Mayank Vermani
Dropwise condensation heat transfer on ion implanted metallic surfaces International Heat Transfer Conference 12, Vol.44, 2002, issue
Liv Diezel, Kyong-Hee Choi, Alfred Leipertz
Correlative Experimental Animal and Human Clinical Retrieval Evaluations of Hydroxyapatite (HA)-Coated and Non-Coated Implants in Orthopaedics and Dentistry Critical Reviews™ in Biomedical Engineering, Vol.28, 2000, issue 3&4
David E. Steflik, Raymond Y. Whitehead, Michael D. Wilson, Carlos Jaramillo, Timothy R. Young, R. Scott Corpe
SEM INVESTIGATION OF CHITOSAN NANOFIBERS PRODUCED BY NANOSPIDER TECHNOLOGY High Temperature Material Processes: An International Quarterly of High-Technology Plasma Processes, Vol.17, 2013, issue 2-3
V. G. Luhin, N. Prokopchuk, K. Vishnevskii, J. Plowucha, Zh. Shashok, Pawel Zukowski

Próximos Artículos

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Portal Digitalde Biblioteca Digital eLibros Revistas Referencias y Libros de Ponencias Colecciones Precios y Políticas de Suscripcione Begell House Contáctenos Language English 中文 Русский Português German French Spain