An Expanded Surgical Suture and Needle Evaluation and Selection Program By a Healthcare Resource Management Group Purchasing Organization

Volume 13, Edição 3, 2003, 16 pages
DOI: 10.1615/JLongTermEffMedImplants.v13.i3.30
Get accessGet access

RESUMO

The purpose of this report is to describe an expanded suture and needle clinical evaluation program jointly designed by hospital representatives of Consorta, Inc. (Rolling Meadows, Illinois), a leading healthcare resource management and group purchasing organization, and United States Surgical/Davis & Geck Sutures (Division of United States Surgical, Norwalk, Connecticut). In this expanded evaluation program, 42 Consorta shareholder hospitals enrolled 1913 surgeons to participate in Phase II of this non-experimental observational study of the clinical performance of surgical needles and sutures. Performance characteristics of the sutures and needles produced by USS/DG that were evaluated in 25,545 surgical procedures included packaging/ease of opening, needle strength and sharpness, tissue drag, knot security, tensile strength, clinically acceptable determinations, and clinically unacceptable determinations.
In these 30-day studies, the surgeons found that the needles and sutures were clinically acceptable in 98.1% of the evaluations. The general, cardiothoracic, and orthopedic surgeons who performed 61.2% of the product evaluations reported that the suture and needle products were clinically acceptable in 98.2% of the evaluations. Nearly half (49.2%) of the evaluations involved the POLYSORB* braided synthetic sutures that received a clinically acceptable rating in 98.2% of the evaluation. The silk suture (SOFSILK*), followed by the monofilament nylon suture (MONOSOF*), were the next most frequently used sutures. The SOFSILK* was found to be clinically acceptable in 99.2% of the evaluations, while MONOSOF* was noted to be clinically acceptable in 98.7% of the evaluations. Surgical needles made by USS/DG Sutures also had a high rating of clinical acceptability (97.9%).

CITADO POR
  1. Burns Lawton R., Bradlow Eric T., Lee J. Andrew, Antonacci Anthony C., Assessment of medical devices: How to conduct comparative technology evaluations of product performance, International Journal of Technology Assessment in Health Care, 23, 4, 2007. Crossref

  2. Dart A.J., Dart C.M., Suture Material: Conventional and Stimuli Responsive, in Comprehensive Biomaterials, 2011. Crossref

  3. Burns Lawton R., Lee J. Andrew, Bradlow Eric T., Antonacci Anthony, Surgeon Evaluation of Suture and Endo-Mechanical Products, Journal of Surgical Research, 141, 2, 2007. Crossref

  4. Dart A.J., Dart C.M., 7.38 Suture Material: Conventional and Stimuli Responsive ☆, in Comprehensive Biomaterials II, 2017. Crossref

  5. Abdelall Esraa S., Stone Richard T., Rajana Nedved Leela, Fales Colten, Bend the Tool, Not the Wrist: An Ergonomic Investigation of Medical Suturing Needle Holder Design and Medical Engineering Solution, Surgical Innovation, 28, 1, 2021. Crossref

  6. Prashant SDhanke, Subodh PUgane, Prakash RDhumal, Hamza TQazi, Emergency intraoperative construction of a suture needle from a hypodermic/injection needle, Nigerian Journal of Surgical Sciences, 28, 2, 2018. Crossref

  7. Dresing Klaus, Langer Martin Franz, Slongo Theddy, Chirurgische Nadeln in Orthopädie und Unfallchirurgie, Operative Orthopädie und Traumatologie, 33, 5, 2021. Crossref

1504 Visualizações do artigo 18 downloads de artigos Métricas
1504 VISUALIZAÇÕES 18 TRANSFERÊNCIAS 7 Crossref CITAÇÕES Google
Scholar
CITAÇÕES

Artigos com conteúdo semelhante:

An Innovative Surgical Suture and Needle Evaluation and Selection Program Journal of Long-Term Effects of Medical Implants, Vol.12, 2002, issue 4
John G. Thacker, George T. Rodeheaver, Richard Edlich, Robin R. Szarmach, Jean Livingston
A Review on the Innovative Surgical Suture and Needle Evaluation and Selection Program Journal of Long-Term Effects of Medical Implants, Vol.27, 2017, issue 2-4
John G. Thacker, George T. Rodeheaver, Richard Edlich, Robin R. Szarmach, Jean Livingston
Syneture™ Stainless STEEL Suture. A Collective Review of Its Performance in Surgical Wound Closure Journal of Long-Term Effects of Medical Implants, Vol.16, 2006, issue 1
Christine C. Scott, William B. Long III, George T. Rodeheaver, Richard Edlich, Samuel P. Winters, Jill Amanda Greene, Kathryne L. Winters, L.D. Britt, Kant Y. Lin, David B. Drake
An Endomechanical Product Evaluation and Selection Program by a Healthcare Resource Management Group Purchasing Organization Journal of Long-Term Effects of Medical Implants, Vol.14, 2004, issue 4
Richard Edlich, Jean Livingston, Robin R. Szarmach
Wound Closure Sutures and Needles: A New Perspective Journal of Environmental Pathology, Toxicology and Oncology, Vol.29, 2010, issue 4
Jill J. Dahlstrom, William B. Long III, Richard Edlich, Jamie J. Clark, Anne G. Wallis, K. Dean Gubler

Próximos artigos

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa Políticas de preços e assinaturas Begell House Contato Language English 中文 Русский Português German French Spain