Inscrição na biblioteca: Guest
Journal of Long-Term Effects of Medical Implants

Publicou 4 edições por ano

ISSN Imprimir: 1050-6934

ISSN On-line: 1940-4379

SJR: 0.184 SNIP: 0.485 CiteScore™:: 1.1 H-Index: 39

Indexed in

Parastomal Hernia Repair

Volume 20, Edição 2, 2010, pp. 133-138
DOI: 10.1615/JLongTermEffMedImplants.v20.i2.60
Get accessGet access

RESUMO

Parastomal hernias remain a daunting challenge to general and colorectal surgeons. Their unique anatomy and alteration of abdominal wall mechanics contribute to a significant recurrence rate and associated morbidity in repair. Recent advances in synthetic and biologic meshes, as well as refinement of laparoscopic surgical techniques, may offer potential improvements in outcome for these patients. We conducted a review of the literature for parastomal hernia repair, including manuscripts specifically addressing the use of synthetic and biologic prostheses. We then chose selected references from these studies to include in this review. Results are summarized to reflect current evidence for use of prostheses and other techniques in the repair of parastomal hernias. Repair of parastomal hernias remains plagued by significant recurrence rates. Recurrence may be higher when other abdominal wall hernias are addressed simultaneously. Synthetic mesh repair appears to reduce recurrence compared with primary suture repair. The use of biologic prostheses may reduce recurrence rate and eliminate the potential for mesh infection. The laparoscopic approach should be individualized to both patient and surgeon factors.

CITADO POR
  1. López-Cano M., Lozoya-Trujillo R., Quiroga S., Sánchez J. L., Vallribera F., Martí M., Jiménez L. M., Armengol-Carrasco M., Espín E., Use of a prosthetic mesh to prevent parastomal hernia during laparoscopic abdominoperineal resection: a randomized controlled trial, Hernia, 16, 6, 2012. Crossref

  2. Valdés-Hernández Javier, Díaz Milanés Juan Antonio, Capitán Morales Luis Cristóbal, del Río la Fuente Francisco Javier, Torres Arcos Cristina, Cañete Gómez Jesús, Oliva Mompeán Fernando, Padillo Ruiz Javier, Prevention of Parastomal Hernia with a Preperitoneal Polypropelene Mesh, Cirugía Española (English Edition), 93, 7, 2015. Crossref

  3. Valdés-Hernández Javier, Díaz Milanés Juan Antonio, Capitán Morales Luis Cristóbal, del Río la Fuente Francisco Javier, Torres Arcos Cristina, Cañete Gómez Jesús, Oliva Mompeán Fernando, Padillo Ruiz Javier, Profilaxis de la hernia paraestomal mediante malla de polipropileno en espacio preperitoneal, Cirugía Española, 93, 7, 2015. Crossref

  4. Frantzides Constantine T., Welle Scott N., Cardiac tamponade as a life-threatening complication in hernia repair, Surgery, 152, 1, 2012. Crossref

  5. Jones Huw G, Rees Michael, Aboumarzouk Omar M, Brown Joshua, Cragg James, Billings Peter, Carter Ben, Chandran Palanichamy, Prosthetic mesh placement for the prevention of parastomal herniation, Cochrane Database of Systematic Reviews, 2018, 7, 2018. Crossref

Próximos artigos

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa Políticas de preços e assinaturas Begell House Contato Language English 中文 Русский Português German French Spain