Evaluation of Microbial Leakage at Implant Abutment Interfact for Different Implant Systems: An In Vitro Study

Том 32, Выпуск 2, 2022, pp. 87-93
DOI: 10.1615/JLongTermEffMedImplants.2022038657
Get accessGet access

Краткое описание

Two-stage implant systems result in gaps and cavities between implant and abutment that can act as a trap for bacteria and thus possibly cause inflammatory reactions in the peri-implant soft tissues. These gaps between the components are inevitable, and their clinical significance has so far been mostly neglected by both manufacturers and clinicians. This study is thus intended to evaluate microbial leakage at implant abutment interface in different implant systems. Four different systems, the Nobel tri-channel, the Nobel conical, the Equinox, and the Straumann, were used for this study. One microliter of a fresh broth suspension of Streptococcus mutans was added to the implant fixture (implant body). The implant was immersed in fresh heart brain infusion and was incubated at 37° for 48 hours. After incubation, 10 μL of the broth was made as lawn culture on sterile agar and the colonies were counted and recorded as colony-forming units per milliliter. Statistical tests were carried out on SPSS software and tests included analysis of variance (ANOVA) and P value was derived using Tukey's honestly significant difference post hoc test. After incubation, results were analyzed by evaluating the microbial leakage from each sample and it was observed that Nobel tri-channel had the least amount of microbial leakage and Equinox had maximum microbial leakage. The difference among all implant systems was statistically significant P < 0.05. The study concluded that least micro-leakage was found in the Nobel tri-channel whereas maximum microbial leakage was present in Equinox and Straumann.

Ключевые слова: implant, microbial leakage, micro gap, bacterial growth
ЛИТЕРАТУРА
  1. Goodacre CJ, Bernal G, Rungcharassaeng K, Kan JY. Clinical complications with implants and implant prostheses. J Prosthet Dent. 2003;90(2):121-32. .

  2. Jansen VK, Conrads G, Richter EJ. Microbial leakage and marginal fit of the implant-abutment interface. Int J Oral Maxillofac Implants. 1997;12(4):527-40. .

  3. Gopal TM, Rohinikumar S, Thiyaneswaran N, Maiti S. Effect of submandibular fossa on implant length in the posterior mandibular region. J Long Term Eff Med Implants. 2020;30(3):219-26. .

  4. Tulsani M, Rohinikumar S, Maiti S, Nesappan T. Impact of level of crestal placement on marginal bone loss: A retrospective institutional study. J Long Term Eff Med Implants. 2020;30(4):227-32. .

  5. Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: A review and proposed criteria of success. Int J Oral Maxillofac Implants. 1986;1(1):11-25. .

  6. Rupawat D, Maiti S, Nallaswamy D, Sivaswamy V. Aesthetic outcome of implants in the anterior zone after socket preservation and conventional implant placement: A retrospective study. J Long Term Eff Med Implants. 2020;30(4):233-9. .

  7. Jansen VK, Conrads G, Richter EJ. Microbial leakage and marginal fit of the implant-abutment interface. Int J Oral Maxillofac Implants. 1997;12(4):527-40. .

  8. Quirynen M, De Soete M, Van Steenberghe D. Infectious risks for oral implants: A review of the literature. Clin Oral Implants Res. 2002;13(1):1-19. .

  9. Broggini N, Mcmanus LM, Hermann JS, Medina RU, Oates TW, Schenk RK, Buser D, Mellonig JT, Cochran DL. Persistent acute inflammation at the implant-abutment interface. J Dent Res. 2003;82(3):232-7. .

  10. Hermann JS, Cochran DL, Hermann JS, Buser D, Schenk RK, Schoolfield JD. Biologic Width around one-and two-piece titanium implants: A histometric evaluation of unloaded nonsubmerged and submerged implants in the canine mandible. Clin Oral Implants Res. 2001;12(6):559-71. .

  11. Passos SP, Gressler May L, Faria R, Ozcan M, Bottino MA. Implant-abutment gap versus microbial colonization: Clinical significance based on a literature review. J Biomed Mater Res B Appl Biomater. 2013;101(7):1321-8. .

  12. Agarwal S, Ashok V, Maiti S. Open-or closed-tray impression technique in implant prosthesis: A dentist's perspective. J Long Term Eff Med Implants. 2020;30(3):219-26. .

  13. Orsini G, Fanali S, Scarano A, Petrone G, di Silvestro S, Piattelli A. Tissue reactions, fluids, and bacterial infiltration in implants retrieved at autopsy: A case report. Int J Oral Maxillofac Implants. 2000;15(2):283-6. .

  14. Adell R, Lekholm U, Rockler BR, Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg. 1981;10(6):387-416. .

  15. Tripodi D, Vantaggiato G, Scarano A, Perrotti V, Piattelli A, Iezzi G, D'Ercole S. An in vitro investigation concerning the bacterial leakage at implants with internal hexagon and Morse taper implant-abutment connections. Implant Dent. 2012;21(4):335-9. .

  16. Traversy MC, Birek P. Fluid and microbial leakage of implant-abutment assembly in vitro. J Dent Res. 1992;71:754. .

  17. Quirynen M, De Soete M, Van Steenberghe D. Infectious risks for oral implants: A review of the literature. Clin Oral Implants Res. 2002;13(1):1-9. .

  18. Harder S, Dimaczek B, Afil Y, Terheyden H, Freitag-Wolf S, Kern M. Molecular leakage at implant-abutment connection-in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration. Clin Oral Investig. 2010;14(4):427-32. .

  19. Aloise JP, Curcio R, Laporta MZ, Rossi L, Da Silva AM, Rapoport A. Microbial leakage through the implant-abutment interface of Morse taper implants in vitro. Clin Oral Implants Res. 2010;21(3):328-35. .

  20. Dias EC, Bisognin ED, Harari ND, Machado SJ, da Silva CP, de Almeida Soares GD, VidigalJr GM. Evaluation of implant-abutment microgap and bacterial leakage in five external-hex implant systems: An in vitro study. Int J Oral Maxillofac Implants. 2012;27(2):346-51. .

  21. Besimo CE. Bacterial leakage into and from prefabricated screw-retained implant-borne crowns in vitro. J Oral Rehabil. 1998;25(6):403-8. .

  22. Traversy MC. Fluid and microbial leakage of implant-abutment assembly in vitro. J Dent Res. 1992;71:754. .

  23. Steinebrunner L, Wolfart S, BoBmann K, Kern M. In vitro evaluation of bacterial leakage along the implant-abutment interface of different implant systems. Int J Oral Maxillofac Implants. 2005;20(6):875-81. .

  24. El Haddad E, Gianni AB, Mancini GE, Cura F, Carinci F. Implant-abutment leaking of replace conical connection nobelbiocare implant system. An in vitro study of the microbiological penetration from external environment to implant-abutment space. Oral Implantol. 2016;9(2):76. .

  25. Tsuge T, Hagiwara Y, Matsumura H. Marginal fit and microgaps of implant-abutment interface with internal anti-rotation configuration. Dent Mater J. 2008;27(1):29-34. .

  26. Do Nascimento C, Barbosa RE, Issa JP, Watanabe E, Ito IY, Junior RA. Bacterial leakage along the implant-abutment interface of premachined or cast components. Int J Oral Maxillofac Surg. 2008;37(2):177-80. .

  27. Rismanchian M, Hatami M, Badrian H, Khalighinejad N, Goroohi H. Evaluation of microgap size and microbial leakage in the connection area of 4 abutments with Straumann (ITI) implant. J Oral Implantol. 2012;38(6): 677-85. .

  28. Edman DC, Keene HJ, Shklair IL, Hoerman KC. Dental floss for implantation and sampling of Streptococcus mutans from approximal surfaces of human teeth. Arch Oral Biology. 1975;20(2):145-8. .

  29. Bisognin ED, Harari ND, Machado SJ, da Silva CP, de Almeida Soares GD, Vidigal GM Jr. Evaluation of implant-abutment microgap and bacterial leakage in five external-hex implant systems: An in vitro study. Int J Oral Maxillofac Implants. 2012;27(2):346-51. .

  30. Saidin S, Kadir MR, Sulaiman E, Kasim NH. Effects of different implant-abutment connections on micromotion and stress distribution: Prediction of microgap formation. J Dent. 2012;40(6):467-74. .

  31. Nassar HI, Abdalla MF. Bacterial leakage of different internal implant/abutment connection. Fut Dent J. 2015;1(1):1-5. .

  32. Lopes de Chaves e Mello Dias EC, Sperandio M, Henrique Napimoga M. Association between implant-abutment microgap and implant circularity to bacterial leakage: An in vitro study using tapered connection implants. Int J Oral Maxillofac Implants. 2018;33(3):505-11. .

  33. Aloise JP, Curcio R, Laporta MZ, Rossi L, Da Silva AM, Rapoport A. Microbial leakage through the implant-abutment interface of Morse taper implants in vitro. Clin Oral Implants Res. 2010;21(3):328-35. .

13550 Просмотры статей 49 Загрузка статей Метрики
13550 ПРОСМОТРЫ 49 ЗАГРУЗКИ Google
Scholar
ЦИТАТЫ

Статьи с похожим содержанием:

Socket Preservation and Implant Insertion in a Smoker With a 10-Year History of Bisphosphonate Use: A Case Report Journal of Long-Term Effects of Medical Implants, Vol.20, 2010, issue 4
Sebastiano Andreana, Carla Beneduce, Sasikumar Sunkara
Bacterial Microleakage at the Implant-Healing Abutment Interface in Two Different Implant Designs: Platform Switching versus Platform Matching Journal of Long-Term Effects of Medical Implants, Vol.31, 2021, issue 1
Mohammad Reza Talebi Ardakani, Mahdi Kadkhodazadeh, Romina Tohidi, Reza Amid
The Influence of Absorbable Subcuticular Staples, Continuous Subcuticular Absorbable Suture, and Percutaneous Metal Skin Staples on Infection in Contaminated Wounds Journal of Long-Term Effects of Medical Implants, Vol.22, 2012, issue 2
George T. Rodeheaver, Pamela F. Rodeheaver, Lisa S. Salopek, Angela Pineros-Fernandez
Comparison of Malondialdehyde Levels among Patients with Sandblasted Acid-Etched and Anodized Surface Dental Implants: A Prospective Clinical Study Journal of Long-Term Effects of Medical Implants, Vol.34, 2024, issue 3
Sheeja S. Varghese, Arvina Rajasekar
Genoprotective Capacity of Alternatively Cultivated Lingzhi or Reishi Medicinal Mushroom, Ganoderma lucidum (Agaricomycetes), Basidiocarps International Journal of Medicinal Mushrooms, Vol.18, 2016, issue 12
Vladan Bajic, Jelena Vukojević, Lada Živković, Mirjana Stajic, Jasmina Ćilerdžić, Biljana Spremo-Potparević

Статьи, принятые к публикации

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Портал Begell Электронная Бибилиотека e-Книги Журналы Справочники и Сборники статей Коллекции Цены и условия подписки Begell House Контакты Language English 中文 Русский Português German French Spain