Syneture™ Stainless STEEL Suture. A Collective Review of Its Performance in Surgical Wound Closure

Том 16, Выпуск 1, 2006, pp. 101-110
DOI: 10.1615/JLongTermEffMedImplants.v16.i1.100
Get accessGet access

Краткое описание

Syneture™ (division of U.S. Surgical, division of Tyco Healthcare, Norwalk, Connecticut, USA) STEEL sutures are monofilament stainless steel sutures composed of 316L stainless steel conforming to ASTM Standard F138 grade 2 (" Stainless steel bar and wire for surgical implant"). STEEL sutures meet all requirements established by the United States Pharmacopeia (USP) for nonabsorbable surgical sutures. Steel sutures are for use in abdominal wound closure, intestinal anastomosis, hernia repair, sternal closure, and skin closure. They are attached to the following types of surgical needles: Roto-Grip™ Needles and SCC Needle. The sutures and needles are packaged in a Mylar™/Tyvek™ outer envelope.
The purposes of this clinical review are two fold. First, we will report the performance of the Syneture™ STEEL suture product in the largest studies of suture performance ever reported in the literature. In addition, we will provide comprehensive information from the surgical literature that highlights the unique benefits of stainless steel sutures for the following wound closure techniques: sternal fixation, abdominal wound repair, inguinal hernia repair, and skin wound closure.
Consorta Inc. (Rolling Meadows, Illinois), a leading healthcare resource management group purchasing organization, and Syneture™, jointly with a clinician task force, designed a reproducible surgical evaluation program for needles and sutures in a large cooperative of healthcare systems. Because of the subjective nature of the more commonly used suture selection techniques, a nonexperimental observational study approach was designed to replace perception of performance characteristics with actual clinical experience. In a report involving 19 Consorta shareholder hospitals, they discussed the preliminary part (Phase I) of a large nonexperimental observational study of the clinical performance of surgical needles and sutures.
Performance characteristics of the sutures and needles produced by Syneture™ that were evaluated in 3407 surgical procedures included packaging/ease of opening, needle strength and sharpness, tissue drag, knot security, tensile strength, clinically acceptable determinations, and clinically unacceptable determinations. In this preliminary study, the surgeons concluded that the needles and sutures were clinically acceptable in 98.1% of the evaluations. Armed with this favorable experience, we wanted to expand this observational study to an entirely new group of shareholder hospitals that had a larger number of participating hospitals (Phase I, 19 hospitals; Phase II, 42 hospitals). This more than doubling of hospital observational base dramatically increased the number of patients and performance evaluations. In the Phase II expanded program involving 42 hospitals, the number of patients (8939) and the number of evaluations (25,545) were more than twofold the preliminary study.
In the phase I multicentric evaluation of Syneture™ surgical sutures, the performance of 9266 sutures was evaluated. Of these performance evaluations, 130 evaluations focused on Syneture™ STEEL sutures. The surgeons were especially pleased by the performance of this suture product, with 129 Syneture™ STEEL products being judged as clinically acceptable in their performance. Only one Syneture™ STEEL suture was judged to be unacceptable in its performance, resulting in a 99.2% acceptability rating.
In the expanded phase II evaluation of Syneture™ suture products, the performance evaluation involved 25,545 surgical suture evaluations. The performance of Syneture™ STEEL sutures was judged in 215 cases. Of these product performance evaluations, 207 were judged to be clinically acceptable in their performance (96.3%). It is important to emphasize that the phase I and phase II observational studies evaluated the performance of other sutures besides monofilament steel sutures. These comprehensive suture and needle performance evaluations included the following additional sutures: Plain Gut, Mild Chromic Gut, Chromic Gut, DEXON™ II, DEXON™ S, MAXON™, BIOSYN™, SOFSILK™, SURGILON™, BRALON™, MONOSOF™, DERMALON™, SURGIDAC™, POLY-SORB™, TI·CRON™, SURGIPRO™, SURGIPRO™ II, NOVAFIL™, VASCUFIL™, and FLEXON™.
Finally, we provide a collective review of the literature that shows the reliable performance of monofilament stainless steel sutures in the following wound closure techniques: sternal fixation, abdominal wound closure, inguinal hernia repair, and skin wound closure.

ЦИТИРОВАНО В
  1. Chu C.C., Materials for absorbable and nonabsorbable surgical sutures, in Biotextiles as Medical Implants, 2013. Crossref

  2. Seitz Jan-Marten, Durisin Martin, Goldman Jeremy, Drelich Jaroslaw W., Recent Advances in Biodegradable Metals for Medical Sutures: A Critical Review, Advanced Healthcare Materials, 4, 13, 2015. Crossref

  3. Pillai Chennakkattu Krishna Sadasivan, Sharma Chandra P., Review Paper: Absorbable Polymeric Surgical Sutures: Chemistry, Production, Properties, Biodegradability, and Performance, Journal of Biomaterials Applications, 25, 4, 2010. Crossref

  4. Venezuela Jeffrey Jones D., Johnston Sean, Dargusch Matthew Simon, The Prospects for Biodegradable Zinc in Wound Closure Applications, Advanced Healthcare Materials, 8, 16, 2019. Crossref

  5. Milenin Andrij, Kustra Piotr, Byrska-Wójcik Dorota, Wróbel Mirosław, Paćko Marek, Sulej-Chojnacka Joanna, Matuszyńska Sława, Płonka Bartłomiej, The effect of in vitro corrosion on the mechanical properties of metallic high strength biodegradable surgical threads, Archives of Civil and Mechanical Engineering, 20, 2, 2020. Crossref

  6. Nizami M.Z.I., Campéon B.D.L., Nishina Y., Electrodeposition of hydroxyapatite and graphene oxide improves the bioactivity of medical grade stainless steel, Materials Today Sustainability, 19, 2022. Crossref

Статьи, принятые к публикации

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Портал Begell Электронная Бибилиотека e-Книги Журналы Справочники и Сборники статей Коллекции Цены и условия подписки Begell House Контакты Language English 中文 Русский Português German French Spain